Liver steatosis: concordance of MR imaging and MR spectroscopic data with histologic grade.

Radiology

Department of Radiology and Biomedical Imaging, Center for Molecular and Functional Imaging, University of California, San Francisco, 185 Berry St, Suite 350, Box 0946, San Francisco, CA 94107, USA.

Published: July 2012

Purpose: To determine if the concordance of magnetic resonance (MR) imaging and MR spectroscopic data with histologic measures of steatosis is affected by histologic magnification level, tissue heterogeneity, or assessment of tissue area versus that of hepatocytes.

Materials And Methods: This study was institutional review board approved and HIPAA compliant. Written informed consent was obtained. In- and out-of-phase MR imaging and MR spectroscopic measures of steatosis were compared in 33 patients with nonalcoholic fatty liver disease and in 15 healthy volunteers. Concordance of MR imaging and MR spectroscopic data with histologic findings was assessed for (a) histologic examination at standard (×40 and ×100) versus high magnification (×200 and ×400), (b) heterogeneity and homogeneity of livers, and (c) percentage of tissue and hepatocytes that contained lipids. Evaluations included linear regression and Fisher exact tests.

Results: In- and out-of-phase MR imaging and MR spectroscopic data were well correlated (R2=0.93) and generally concordant with histologic measures. Patients in whom MR fat fractions were higher than expected compared with steatosis grades at standard magnification histologic examination were upgraded significantly more often when high magnification was used than were the remaining patients (100% [10 of 10] vs 47% [7 of 15], P<.01). MR imaging and MR spectroscopic data of homogeneous livers were significantly more likely than those of heterogeneous livers to be concordant with steatosis grades when high magnification was used (81% [13 of 16] vs 47% [8 of 17], P<.05). For all patients, percentage of fat in tissue was lower than that in hepatocytes, which affected individual patients, but not the overall correlation.

Conclusion: MR imaging and MR spectroscopic data were generally concordant with histologic measures of steatosis. Discordance between them may reflect differences in magnification at histologic examination and in liver heterogeneity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3380413PMC
http://dx.doi.org/10.1148/radiol.12110673DOI Listing

Publication Analysis

Top Keywords

imaging spectroscopic
20
spectroscopic data
16
data histologic
12
concordance imaging
8
histologic measures
8
measures steatosis
8
in- out-of-phase
8
out-of-phase imaging
8
histologic examination
8
high magnification
8

Similar Publications

Biosensors based on DNA aptamer receptors are increasingly used in diagnostic applications. To improve the sensitivity and specificity of aptasensors, parameters affecting the stability and binding efficiency of the receptor layer need to be identified and studied. For example, the blocking step, i.

View Article and Find Full Text PDF

A bio-fabrication approach is a novel way to develop chitosan-stabilized magnesium oxide nanomaterials (cMgO-NMs). The process involves utilizing polymeric chitosan as the reducing and stabilizing agent. The characteristics of the developed cMgO-NMs were determined using various spectroscopical techniques.

View Article and Find Full Text PDF

Precise surgical resection of prostate cancer (PCa) is a significant clinical challenge due to the impact of positive surgical margins on postoperative outcomes. Fluorescence-guided surgery (FGS) enables real-time tumor visualization using fluorescent probes. In this study, we synthesized and evaluated an indocyanine green (ICG)-based PSMA-targeted near-infrared probe, , for intraoperative imaging of PCa lesions.

View Article and Find Full Text PDF

Terahertz conductivity of two-dimensional materials: a review.

J Phys Condens Matter

January 2025

ECE Department, University of Wisconsin at Madison, 1415 Engineering Dr, Rm 3442, Madison, WI 53706, USA, Madison, Wisconsin, 53706, UNITED STATES.

Two-dimensional (2D) van der Waals materials are shaping the landscape of next-generation devices, offering significant technological value thanks to their unique, tunable, and layer-dependent electronic and optoelectronic properties. Time-domain spectroscopic techniques at terahertz (THz) frequencies offer noninvasive, contact-free methods for characterizing the dynamics of carriers in 2D materials. They also pave the path toward the applications of 2D materials in detection, imaging, manufacturing, and communication within the increasingly important THz frequency range.

View Article and Find Full Text PDF

The cyano-cyclopentadiene molecule (CN-CH) has attracted significant interest since its detection in the interstellar medium, but the radical (CN-CH) and anionic (CN-CH) forms of cyano-cyclopentadiene have not been studied. The cyano-cyclopentadienyl radical (CN-Cp) has a strong dipole moment, rendering it an ideal system for vibrational and rotational spectroscopy. We report an investigation of the cryogenically cooled cyano-cyclopentadienide anion (CN-Cp) using high-resolution photoelectron imaging, photodetachment spectroscopy, and resonant photoelectron imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!