Blowfly flight characteristics are shaped by environmental features and controlled by optic flow information.

J Exp Biol

Department of Neurobiology and Center of Excellence, Cognitive Interaction Technology, Bielefeld University, D-33501 Bielefeld, Germany.

Published: July 2012

Blowfly flight consists of two main components, saccadic turns and intervals of mostly straight gaze direction, although, as a consequence of inertia, flight trajectories usually change direction smoothly. We investigated how flight behavior changes depending on the surroundings and how saccadic turns and intersaccadic translational movements might be controlled in arenas of different width with and without obstacles. Blowflies do not fly in straight trajectories, even when traversing straight flight arenas; rather, they fly in meandering trajectories. Flight speed and the amplitude of meanders increase with arena width. Although saccade duration is largely constant, peak angular velocity and succession into either direction are variable and depend on the visual surroundings. Saccade rate and amplitude also vary with arena layout and are correlated with the 'time-to-contact' to the arena wall. We provide evidence that both saccade and velocity control rely to a large extent on the intersaccadic optic flow generated in eye regions looking well in front of the fly, rather than in the lateral visual field, where the optic flow at least during forward flight tends to be strongest.

Download full-text PDF

Source
http://dx.doi.org/10.1242/jeb.061713DOI Listing

Publication Analysis

Top Keywords

optic flow
12
blowfly flight
8
saccadic turns
8
flight
6
flight characteristics
4
characteristics shaped
4
shaped environmental
4
environmental features
4
features controlled
4
controlled optic
4

Similar Publications

Early ultrastructural damage in retina and optic nerve following intraocular pressure elevation.

Vision Res

January 2025

Instituto de Biofísica Carlos Chagas Filho, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brazil.

Elevated intraocular pressure (IOP) is a significant risk factor for glaucoma, causing structural and functional damage to the eye. Increased IOP compromises the metabolic and structural integrity of retinal ganglion cell (RGC) axons, leading to progressive degeneration and influencing the ocular immune response. This study investigated early cellular and molecular changes in the retina and optic nerve (ON) following ocular hypertension (OHT).

View Article and Find Full Text PDF

A 73-year-old male with a history of incidentally diagnosed Paget disease of bone affecting the skull and left orbit 2 years prior presented with 3 months of vision loss, proptosis, and periorbital swelling of the OS. Examination showed best-corrected Snellen visual acuity of 20/150 in the affected eye, intact motility, 7 mm of relative proptosis, significant dilated and tortuous "corkscrew" conjunctival vessels, serous choroidal and retinal detachments, optic nerve hyperemia, and venous tortuosity and dilation. Although the bony lesions in the left orbit were stable from 1 year prior on imaging, the diagnostic angiogram demonstrated osseous blush and hypervascularity of the lesion.

View Article and Find Full Text PDF

Simultaneous or separate detection of heavy metal ions Hg and Ag based on lateral flow assays.

Mikrochim Acta

January 2025

Department of General Surgery, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, 266035, China.

A lateral flow assay (LFA) was developed for the simultaneous or separate detection of mercury ion and silver ion based on isothermal nucleic acid amplification. T-Hg-T and C-Ag-C were utilized in the isothermal nucleic acid amplification strategy to form specific complementary base pairs. Under the action of KF polymerase and endonuclease Nt.

View Article and Find Full Text PDF

We describe a patient with severe Arnold Chiari Malformation and syringomyelia who underwent gynecological laparoscopy in an emergency context; no brain imaging was available. We here report the successful use of optic nerve sheath diameter (ONSD) and middle cerebral artery (MCA) velocity measurements as surrogate monitoring for cerebral blood flow and intracranial pressure, respectively. MCA velocity was low when assessed after peritoneal insufflation and ONSD increased to 6.

View Article and Find Full Text PDF

Aim: To compare the macular and optic nerve perfusion and vascular architecture using optical coherence tomography angiography (OCTA) in normal eyes of Egyptian (Caucasians) and South Asian (Asians) volunteers.

Methods: Cross-sectional analytical OCTA study performed on 90 eyes of South Asian (=45) and Egyptians (=45) were analyzed. All participants underwent best-corrected visual acuity test, slit lamp, and fundus examination.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!