Objectives: Left ventricular end systolic pressure (LV ESP) is important in assessing left ventricular performance and is usually derived from prediction equations. It is unknown whether these equations are accurate at rest or following exercise in a young, healthy population.

Design: Measured LV ESP vs. LV ESP values from the prediction equations were compared at rest, 15 min and 30 min following peak aerobic exercise in 60 participants.

Methods: LV ESP was obtained by applanation tonometry at rest, 15 min post and 30 min post peak cycle exercise.

Results: Measured LV ESP was significantly lower (p<0.05) at all time points in comparison to the two calculated values. Measured LV ESP decreased significantly from rest at both the post15 and post30 time points (p<0.05) and changed differently in comparison to the calculated values (significant interaction; p<0.05). The two LV ESP equations were also significantly different from each other (p<0.05) and changed differently over time (significant interaction; p<0.05).

Conclusions: The two commonly used prediction equations did not accurately predict either resting or post exercise LV ESP in a young, healthy population. Thus, LV ESP needs to be individually determined in young, healthy participants. Non-invasive measurement through applanation tonometry appears to allow for a more accurate determination of LV ESP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3479353PMC
http://dx.doi.org/10.1016/j.jsams.2012.05.003DOI Listing

Publication Analysis

Top Keywords

left ventricular
12
ventricular systolic
8
systolic pressure
8
prediction equations
8
measured esp
8
rest min
8
min post
8
esp
5
validity predicting
4
predicting left
4

Similar Publications

Background: Atrial fibrillation (AF) is the most prevalent arrhythmia encountered in clinical practice. Triglyceride glucose index (Tyg), a convenient evaluation variable for insulin resistance, has shown associations with adverse cardiovascular outcomes. However, studies on the Tyg index's predictive value for adverse prognosis in patients with AF without diabetes are lacking.

View Article and Find Full Text PDF

This study investigated the correlation between quantitative echocardiographic characteristics within 3 days of birth and necrotizing enterocolitis (NEC) and its severity in preterm infants. A retrospective study was conducted on 168 preterm infants with a gestational age of < 34 weeks. Patients were categorized into NEC and non-NEC groups.

View Article and Find Full Text PDF

Background: The benefit of mechanical circulatory support (MCS) with Impella (Abiomed, Inc, Danvers, MA) for patients undergoing non-emergent, high-risk percutaneous coronary intervention (HR-PCI) is unclear and currently the subject of a large randomized clinical trial (RCT), PROTECT IV. While contemporary registry data from PROTECT III demonstrated improvement of outcomes with Impella when compared with historical data (PROTECT II), there is lack of direct comparison to the HR-PCI cohort that did not receive Impella support.

Methods: We retrospectively identified patients from our institution meeting PROTECT III inclusion criteria (left ventricular ejection fraction [LVEF] <35% with unprotected left main or last remaining vessel or LVEF <30% undergoing multivessel PCI), and compared this group (NonIMP) to the published outcomes data from the PROTECT III registry (IMP).

View Article and Find Full Text PDF

Background: The assessment of left ventricular (LV) systolic function and quantification of LV ejection fraction (EF) in patients with atrial fibrillation (AF) can be difficult. We previously demonstrated that LV volume changes over the 100 ms of systole (LVEF) can be used as a measure of LV systolic function.

Objective: We sought to evaluate the applicability of LVEF in AF patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!