Aim: To investigate the reliability of massive hepatectomy models by using clip techniques.
Methods: We analyzed anatomical findings in 100 mice following massive hepatectomy induced by liver reduction > 70%. The impact of various factors in the different models was also analyzed, including learning curves, operative time, survival curves, and histopathological findings.
Results: According to anatomical results, models with 75%, 80%, and 90% hepatectomy produced massive hepatectomy. Learning curves and operative times were most optimal with the clip technique. Each hepatectomy performed using the clip technique produced a reasonable survival curve, and there were no differences in histopathological findings between the suture and clip techniques.
Conclusion: Massive hepatectomy by the clip technique is simple and can provide reliable and relevant data.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3374979 | PMC |
http://dx.doi.org/10.3748/wjg.v18.i22.2767 | DOI Listing |
Rev Gastroenterol Peru
January 2025
Universidad de Caldas, Manizales, Colombia.
Esophago-jejunal anastomoses fistula could be mortal. Currently there is a wide therapeutic measure ranging from conservative management, endoscopic therapy and surgery. Endoscopic management has been positioned above other strategies due to minimal invasion which improves survival and reduces mortality.
View Article and Find Full Text PDFArthroplast Today
December 2024
Department of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA.
Background: Robotic-assisted total knee arthroplasty (RA-TKA) was introduced to provide surgeons with virtual preoperative planning and intraoperative information to achieve the desired surgical goals in an effort to improve patient outcomes. The purpose of this study was to compare clinical outcomes and patient-reported outcome measures following primary TKA using RA-TKA vs manual instrumentation.
Methods: This was a retrospective cohort review study comparing 393 primary RA-TKAs vs 312 manual TKAs at a minimum 2-year follow-up.
Oral Maxillofac Surg
January 2025
Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Steiner Landstraße 123, Krems an der Donau, 3500, Austria.
Purpose: Precise implant placement is essential for optimal functional and aesthetic outcomes. Digital technologies, such as computer-assisted implant surgery (CAIS), have improved implant outcomes. However, conventional methods such as static and dynamic CAIS (dCAIS) require complex equipment.
View Article and Find Full Text PDFAust Occup Ther J
February 2025
School of Health and Medical Sciences, University of Southern Queensland, Ipswich, Australia.
Introduction: The Modified Interest Checklist (MIC) is a tool used by therapists to understand past and present occupational engagement, however, is now outdated and lacks contemporary occupations. The aim of this study was to develop an updated valid and reliable checklist tool inclusive of contemporary leisure activities for clinical practice.
Methods: The study consisted of four phases, including feedback in relation to the MIC, two phases of development of an updated tool, and occupational therapists' opinions on the tool.
Endoscopy
December 2025
Department of Gastroenterology, Suzuka General Hospital, Suzuka, Japan.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!