A novel image-processing procedure is proposed for the analysis of sequences of two-dimensional projection images. Sudden events like the merging of bubbles in an evolving foam can be detected and spatio-temporally located in a given projection image sequence. The procedure is based on optical flow computations extended by a forward-backward check for each time step. Compared with prior methods, efficient suppression of noise or false events is achieved owing to uniform foam motion, and the reliability of detection is thus increased. The applicability of the proposed procedure in combination with synchrotron radiography is illustrated by a series of characteristic studies of foams of different kind. First, the detection of single-bubble collapses in aqueous foams is considered. Second, a spatial distribution of coalescence events in metals foamed in casting molds is estimated. Finally, the structural stability of polymer foams containing admixed solid nanoparticles is examined.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S0909049512015099DOI Listing

Publication Analysis

Top Keywords

optical flow
8
projection image
8
coalescence analysis
4
analysis evolving
4
foams
4
evolving foams
4
foams optical
4
flow computation
4
computation projection
4
image sequences
4

Similar Publications

Background: To compare the characteristics of type 1 macular neovascularization (MNV) and the surrounding choriocapillaris (CC) perfusion in patients with neovascular age-related macular degeneration (nAMD) versus those with pachychoroid neovasculopathy (PNV) using swept-source optical coherence tomography angiography (SS-OCTA).

Methods: This retrospective study included 64 treatment-naïve eyes (37 nAMD, 27 PNV) with type 1 MNV. SS-OCTA images were analysed to measure MNV area and perimeter, and CC flow deficits (FD) in five concentric rings surrounding the lesion.

View Article and Find Full Text PDF

Understanding renal pelvis pressure (P) during ureteroscopy (URS) has become increasingly important. High irrigation rates, desirable to maintain visualization and limit thermal dose, can increase P. Use of a multi-channel ureteroscope (m-ureteroscope) with a dedicated drainage channel is one strategy that may facilitate simultaneous low P and high flowrate.

View Article and Find Full Text PDF

Acquiring gait metrics and anthropometric data is crucial for evaluating an individual's physical status. Automating this assessment process alleviates the burden on healthcare professionals and accelerates patient monitoring. Current automation techniques depend on specific, expensive systems such as OptoGait or MuscleLAB, which necessitate training and physical space.

View Article and Find Full Text PDF

X-ray spectroscopies are uniquely poised to describe the geometric and electronic structure of metalloenzyme active sites under a wide variety of sample conditions. UV/Vis (ultraviolet/visible) spectroscopy is a similarly well-established technique that can identify and quantify catalytic intermediates. The work described here reports the first simultaneous collection of full in situ UV/Vis and high-energy resolution fluorescence detected x-ray absorption spectra.

View Article and Find Full Text PDF

Chiral exceptional point enhanced active tuning and nonreciprocity in micro-resonators.

Light Sci Appl

January 2025

Department of Electrical and Computer Engineering, University of Delaware, Newark, Delaware, 19716, USA.

Exceptional points (EPs) have been extensively explored in mechanical, acoustic, plasmonic, and photonic systems. However, little is known about the role of EPs in tailoring the dynamic tunability of optical devices. A specific type of EPs known as chiral EPs has recently attracted much attention for controlling the flow of light and for building sensors with better responsivity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!