A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Magnamosis III: delivery of a magnetic compression anastomosis device using minimally invasive endoscopic techniques. | LitMetric

Purpose: Magnamosis creates a secure sutureless anastomosis through magnetic compression. In this study, we further develop and test delivery devices capable of creating a secure duodeno-colonic anastomosis using available minimally invasive endoscopic techniques.

Methods: Eight pigs underwent general anesthesia. Colonoscopy was used to deliver 1 magnetic ring to the hepatic flexure. Simultaneously, upper endoscopy delivered the other magnetic ring into the duodenum using a variety of techniques. The 2 magnetic rings were brought into magnetic proximity under laparoscopic guidance. The pigs were recovered and examined daily followed by sacrificing at 1, 2, 4, and 6 weeks.

Results: The device designed to deliver and release each magnetic ring evolved from using a guide wire and balloon devices to redesigning the magnetic ring casing with a groove to accommodate an endoscopic snare. Laparoscopic visualization assured safe magnet mating of intestinal segments. The duodeno-colonic anastomoses created with the snare yielded widely patent anastomoses. In vitro testing revealed excellent burst pressure. Histology revealed complete healing as early as 1 week.

Conclusion: We redesigned the magnamosis device to facilitate delivery by endoscopic techniques. The snare technique allows endoscopic positioning and controlled release of the magnetic rings for a secure side-to-side duodeno-colonic anastomosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpedsurg.2012.03.042DOI Listing

Publication Analysis

Top Keywords

magnetic ring
16
magnetic
9
magnetic compression
8
minimally invasive
8
invasive endoscopic
8
endoscopic techniques
8
duodeno-colonic anastomosis
8
magnetic rings
8
release magnetic
8
endoscopic
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!