A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of rest temperature, contact activation, and sample technique on canine thrombelastography. | LitMetric

Objective: To determine the effects of rest temperature, contact activation (CA), and sample collection technique on thrombelastography (TEG) using canine whole blood.

Design: Prospective, experimental study.

Setting: University-based research facility.

Animals: Twelve healthy, adult, mixed-breed dogs.

Interventions: Blood was collected by jugular venipuncture. Tubes containing 3.2% sodium citrate, with and without 75 μg/mL corn trypsin inhibitor (CTI), were filled by vacuum. Samples rested for 30 minutes at 3 temperatures: 37°C, room temperature (RT, 20-22°C), or warmed to 37°C 5 minutes prior to analysis (prewarmed). Samples were analyzed at 37°C. CTI-treated samples were analyzed with and without 1:50,000 tissue factor (TF) as activator. Six dogs were also tested similarly using a needle/syringe collection technique.

Measurement And Main Results: Prewarmed samples exhibited greater MA compared to RT (55.5 ± 7.2 mm vs. 53.5 ± 6.0, P< 0.05), while 37°C samples exhibited a steeper angle (56.7 ± 10.4°C vs. 52.4 ± 8.6°C) and greater MA (55.9 ± 7.5 mm vs. 53.5 ± 6.0 mm) than RT samples (both P< 0.05). CTI-treated samples were hypocoagulable (R time 45 min [7.5-56.8 min], angle 8.2°C [5.1-42.5°C], MA 29.2 ± 9.7 mm, P< 0.001), with TF activation returning all but the angle (42.5 ± 7.6°C) to values similar to citrated samples (angle = 56.7 ± 10.4°C, P = 0.017). Collection using a syringe/needle method revealed a shorter R time for prewarmed samples only (R time 4.7 ± 0.7 min, vs. 5.6 ± 0.8 min for vacuum-collected samples, P = 0.008).

Conclusions: Even in the absence of exogenous activators, CA has an impact on canine TEG results. The effects of rest temperatures and sample collection technique on TEG appear to be minimal.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1476-4431.2012.00730.xDOI Listing

Publication Analysis

Top Keywords

effects rest
12
prewarmed samples
12
samples
10
rest temperature
8
temperature contact
8
contact activation
8
activation sample
8
sample collection
8
collection technique
8
samples analyzed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!