A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Indications for inferior vena cava filter placement: do physicians comply with guidelines? | LitMetric

Purpose: Inferior vena cava (IVC) filter placement has increased significantly over the past few decades, but indications for filter placement vary widely depending on which professional society recommendations are followed, and it is uncertain how compliant physicians are in adhering to guidelines. This study assessed documented indications for IVC filter placement and evaluated compliance with standards set by the American College of Chest Physicians (ACCP) and the Society of Interventional Radiology (SIR).

Materials And Methods: A single-center, retrospective medical record review in a metropolitan, 652-bed, acute care, teaching hospital. Inpatient filter placement over a 26-month period was reviewed. The study measured compliance with established guidelines, relationship of medical specialty to filter placement, and evaluation of self-referral patterns among physicians.

Results: Compliance with established ACCP guidelines was poor regardless of whether the IVC filter insertion was performed by interventional radiology (IR; 43.5%), vascular surgery (VS; 39.9%), or interventional cardiology (IC; 33.3%) staff. Compliance with the less restrictive SIR guidelines was better (77.5%, 77.1%, and 80% for IR, VS, and IC, respectively). There was a greater degree of guideline compliance when filter placement was recommended by internal medicine (IM)-trained physicians than by non-IM-trained physicians: 46.3% of IR-placed filters requested by IM physicians met ACCP criteria whereas only 24.0% of filters recommended by non-IM specialties were compliant with criteria (P = .03). In the VS group, these compliance rates were 45.8% and 31.5%, respectively (P = .03). Among IR-placed filters, 84.0% of IM-recommended filter placements were compliant with SIR guidelines, versus only 48.0% of non-IM-recommended placements (P ≤ .001). In the VS group, these compliance rates were 87.8% and 69.6%, respectively (P ≤ .001).

Conclusions: There is poor physician compliance with guidelines for IVC filter placement. Most filter indications meeting SIR guidelines are for patients classified as "falls risks," failures of anticoagulation, patients with limited cardiopulmonary reserve and patients non compliant with anticoagulation medications. This single-center study suggests a need for harmonization of current guidelines espoused by professional societies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2012.04.017DOI Listing

Publication Analysis

Top Keywords

filter placement
32
ivc filter
16
sir guidelines
12
filter
11
inferior vena
8
vena cava
8
placement
8
guidelines
8
compliance
8
interventional radiology
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!