A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Laser in situ keratomileusis application for myopia over minus 14 diopter with long-term follow-up. | LitMetric

Unlabelled: To evaluate the results of laser in situ keratomileusis (LASIK) for extremely high myopia with a minimum follow-up of 10 years. Istanbul Surgery Hospital, Istanbul, Turkey. Extremely high myopic patients treated with LASIK between 1995 and 1997 with a minimum follow-up of 10 years are reviewed retrospectively. Cases over 14 diopters (D) of myopia were included in the study. From 143 eyes with high myopia greater than -14 D operated on between 1995 and 1997, 39 eyes (26 patients) were available for 10-year follow-up.

Results: The manifest average spherical equivalent refraction was -21.7 ± 5.8 D prior to surgery. This value became -6.0 ± 3.3 D after at least 10 years of follow-up. The regression was -6.1 ± 2.2 D in the period starting from the first month of the follow-up until the last control. The uncorrected visual acuity was 0.07 ± 0.1 at the last follow-up. The mean preoperative best-corrected visual acuity (BCVA) was 0.22 ± 0.12 and 0.30 ± 0.17 postoperatively (p < 0.001). Loss or gain of one line or more at the BCVA in the last control were 10.3 and 53.8 %, respectively. The safety and efficacy indexes are 1.56 ± 0.95 and 0.29 ± 0.4, respectively. No corneal ectasias were noted at follow-up. Although LASIK gives reliable results with high degrees of myopia, significant regression develops in the long term.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10792-012-9595-4DOI Listing

Publication Analysis

Top Keywords

laser situ
8
situ keratomileusis
8
extremely high
8
high myopia
8
minimum follow-up
8
follow-up 10 years
8
1995 1997
8
visual acuity
8
follow-up
6
keratomileusis application
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!