Screw driver: an unusual cause of cervical spinal cord injury.

BMJ Case Rep

Department of Surgery, Division of Neurological Surgery, Federal Medical Centre, Ido-Ekiti, Nigeria.

Published: September 2011

Non-missile penetrating spinal injuries are rare. Screw driver injury, more especially to the cervical spine, represents an even rarer subset. To our knowledge, this is the first reported case from West Africa of cervical spinal cord injury from a screw driver. A middle-aged man was stabbed from the back with a screw driver. He presented with right-sided C4 Brown-Sequard syndrome with the impaling object in situ. Cervical spine x-rays showed the screw driver to have gone into the spine between the spinous processes of C4 and C5, traversing the spinal canal and lodged in the anterior part of the C4/5 intervertebral disc space. C4 and C5 laminectomies were performed and the screw driver removed under vision. The object was found to have traversed the right side of the cervical spinal cord. The dural tear was repaired. He had some neurologic improvement initially, but later declined. He died from severe pulmonary complications 2 weeks postinjury. Screw driver represents an unusual cause of non-missile penetrating cervical spinal injury. Its neurological effects and complications of the cord injury lead to significant morbidity and mortality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3176377PMC
http://dx.doi.org/10.1136/bcr.06.2011.4309DOI Listing

Publication Analysis

Top Keywords

screw driver
28
cervical spinal
16
spinal cord
12
cord injury
12
non-missile penetrating
8
cervical spine
8
screw
7
cervical
6
spinal
6
driver
6

Similar Publications

A handheld fiber-optic tissue sensing device for spine surgery.

PLoS One

December 2024

Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Delft, The Netherlands.

The demographic shift has increased the demand for surgical interventions to address age-related degenerative diseases, such as spinal fusion. Accurate placement of pedicle screws, crucial for successful spinal fusion, varies widely with physician experience. Integrating tissue sensing into spine surgical instruments allows intraoperative examination of tissue properties, providing surgeons with additional information to prevent screw misplacement.

View Article and Find Full Text PDF

Objective: The authors investigated the predictors of cost of admission (CoA) for robot-assisted pedicle screw placement to assess the value of robotic systems in spine operations.

Methods: Demographic, operative, and postoperative variables were retrospectively collected from 506 patients undergoing robot-assisted spine surgery utilizing the ExcelsiusGPS robot at two high-volume tertiary care centers from 2017 to 2023. Perioperative parameters were evaluated against total hospital admission cost utilizing the Kruskal-Wallis and Wilcoxon rank-sum tests followed by multivariable linear regression.

View Article and Find Full Text PDF

Helix breakage during left bundle pacing area implantation.

Pacing Clin Electrophysiol

September 2024

Cardiovascular Department, University of Siena, Siena, Italy.

A left bundle pacing stimulation pacemaker was implanted using stylet driver lead. The screw incarceration occurred after positioning of the lead. The screw rupture occurred during lead retraction; the distal portion of the screw remained incarcerated at the interventricular septum.

View Article and Find Full Text PDF

Background: A novel pelvic fixation screw fusion device (iFuse Bedrock Granite implant) was designed to promote bony fusion through self-harvesting fenestrations throughout the outer screw shank. Bone on-growth and in-growth using this design have been demonstrated in a sheep model, but data from human subjects have not been reported. A 66-year-old medically complex female with 2 prior spine fusions developed spondylodiscitis cephalad to a prior fusion, requiring the removal of instrumentation, which included screw fusion devices.

View Article and Find Full Text PDF

Purpose: To assess, in a large population of Adult Spinal Deformity (ASD) patients, the true interest of varying the upper anchors as a protective measure against Proximal Junctional Kyphosis (PJK), by analyzing and comparing 2 groups of patients defined according to their proximal construct. Another objective of the study is to look for any other factors, radiological or clinical, that would affect the occurrence of the proximal failure.

Methods: Retrospective review of a prospective ASD database collected from 5 centers.

View Article and Find Full Text PDF