Transcardiac conducted electrical weapon (TASER) probe deployments: incidence and outcomes.

J Emerg Med

Department of Emergency Medicine, Wake Forest University School of Medicine, Winston Salem, North Carolina 27106, USA.

Published: December 2012

Background: TASER (TASER International, Scottsdale, AZ) conducted electrical weapons (CEWs) are commonly used by law enforcement officers. Although animal studies have suggested that transcardiac CEW discharges may produce direct cardiac effects, this has not been demonstrated in human studies.

Objectives: This study sought to determine the incidence and outcomes of transcardiac CEW probe impact locations in a large series of actual CEW deployments.

Methods: A multi-center database of consecutive CEW uses by law enforcement officers was retrospectively reviewed. Case report forms were independently reviewed by three investigators to identify cases with paired probe configurations potentially producing a transcardiac discharge vector. Descriptive analysis was performed and inter-rater reliability was assessed.

Results: Among 1201 total CEW uses, 813 included probe deployments and 178 cases had paired anterior probe impacts potentially capable of producing a transcardiac discharge vector. This represents 14.8% of all CEW uses (95% confidence interval [CI] 12.9-16.9%) and 21.9% of CEW uses in probe mode (95% CI 19.1-24.9%). Inter-rater agreement was very good, with kappa = 0.82. There were no immediate deaths in any cases (97.5% CI 0.0-0.3%) to suggest a cardiac dysrhythmia, including those with transcardiac discharge vector.

Conclusion: CEW deployments with probe impact configurations capable of producing a transcardiac discharge occur in a minority of cases in field use conditions. None of these cases, transcardiac or otherwise, produced immediately fatal dysrhythmias. These data support the overall safety of CEWs and provide a benchmark estimate of the likelihood of transcardiac discharge vectors occurring in field use of CEWs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jemermed.2012.03.022DOI Listing

Publication Analysis

Top Keywords

transcardiac discharge
20
producing transcardiac
12
transcardiac
9
conducted electrical
8
probe deployments
8
incidence outcomes
8
law enforcement
8
enforcement officers
8
cew
8
transcardiac cew
8

Similar Publications

Background: Although angiotensin II receptor blockers (ARBs) have been shown to have anti-inflammatory effects on infarcted myocardium in experimental models, little is known in humans. Stromal cell-derived factor-1α (SDF-1α), a pro-inflammatory chemokine, is released from infarcted tissue in patients with acute myocardial infarction (AMI). This study examined whether ARBs suppress SDF-1α production in the infarcted lesion in patients with AMI.

View Article and Find Full Text PDF

Background: Case reports of cardiac arrest in temporal proximity to Conducted Electrical Weapon(CEW) exposure raise legitimate concerns about this as a rare possibility. In this pilot study, we respectfully navigate the oversight and regulatory hurdles and demonstrate the intra-shock electrocardiographic effects of an intentional transcardiac CEW discharge using subcutaneous probes placed directly across the precordium of patients with a previously implanted intracardiac EKG sensing lead.

Methods: Adults scheduled to undergo diagnostic EP studies or replacement of an implanted cardiac device were enrolled.

View Article and Find Full Text PDF

Cardiac injuries caused by knives and firearms are slightly increasing in our environment. We report the case of a 43-year-old male patient with a transmediastinal gunshot wound (TGSW) and a through-and-through cardiac wound who was hemodynamically stable upon his admission. He had an entrance wound below the left clavicle, with no exit wound, and decreased breath sounds in the right hemithorax.

View Article and Find Full Text PDF

Background: TASER (TASER International, Scottsdale, AZ) conducted electrical weapons (CEWs) are commonly used by law enforcement officers. Although animal studies have suggested that transcardiac CEW discharges may produce direct cardiac effects, this has not been demonstrated in human studies.

Objectives: This study sought to determine the incidence and outcomes of transcardiac CEW probe impact locations in a large series of actual CEW deployments.

View Article and Find Full Text PDF

Background: Data from our previous studies indicate that Taser X26 stun devices can acutely alter cardiac function in swine. We hypothesized that most transcardiac discharge vectors would capture ventricular rhythm, but that other vectors, not traversing the heart, would fail to capture the ventricular rhythm.

Methods: Using an Institutional Animal Care and Use Committee (IACUC) approved protocol, four Yorkshire pigs (25-36 kg) were anesthetized, paralyzed with succinylcholine (2 mg/kg), and then exposed to 10 second discharges from a police-issue Taser X26.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!