Complications of chlorine inhalation in a pediatric chemical burn patient: a case report.

J Burn Care Res

Wound Healing Research Group, Department of Surgery, Division of Plastic Surgery, University of Alberta, Edmonton, Canada.

Published: December 2012

The majority of burn injuries in the pediatric population occur at home, and a significant proportion are the result of exposure to household cleaning products. A common injury-causing agent is bleach, which has the potential to release chlorine gas, a potent respiratory irritant that leads to the added risk of inhalation injury. The survival of pediatric patients with chemical burns is extremely high, and the 3 strongest predictors of mortality are large burn size, age <48 months, and the presence of inhalation injury. The authors present a rare case of a pediatric fatality from a chemical bleach burn that resulted in acute respiratory distress syndrome as well as hemodynamic and pulmonary instability that required extracorporeal membrane oxygenation. The authors critically appraised the management of this patient to determine the possible effect certain events had on the unexpected and poor outcome of this patient, including fluid resuscitation, the effect of the chemical inhalation injury, sedation, and the need for invasive extracorporeal membrane oxygenation life support.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BCR.0b013e318254d1c8DOI Listing

Publication Analysis

Top Keywords

complications chlorine
4
chlorine inhalation
4
inhalation pediatric
4
pediatric chemical
4
chemical burn
4
burn patient
4
patient case
4
case report
4
report majority
4
majority burn
4

Similar Publications

Phase-Engineered ZrO for Tuning Catalytic Oxidation of Dichloromethane Over W/ZrO:Zr-Doped WO Clusters and the Hydrolysis-Oxidation Mechanism.

Environ Sci Technol

January 2025

State Key Laboratory of Green Chemical Engineering and Industrial Catalysis, Research Institute of Industrial Catalysis, School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, PR China.

Catalytic elimination through an oxidative decomposition pathway is the most promising candidate for the purification of chlorinated volatile organic compound (CVOC) pollutants, but the complicated mechanisms and the formation pathways of hydrogenated byproducts still need to be clearly revealed. Herein, W/ZrO, as a structure-tunable catalyst, is used to catalytically oxidize dichloromethane (DCM) and clarify the formation pathway of monochloromethane (MCM). Crystal engineering of ZrO tailors surface WO species; practically, the predominant Zr-WO clusters and crystalline WO can be obtained on monoclinic (m-ZrO) and tetragonal (t-ZrO) phases.

View Article and Find Full Text PDF

[Vacuum ultraviolet laser dissociation and proteomic analysis of halogenated peptides].

Se Pu

February 2025

CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.

Chemical modifications are widely used in research fields such as quantitative proteomics and interaction analyses. Chemical-modification targets can be roughly divided into four categories, including those that integrate isotope labels for quantification purposes, probe the structures of proteins through covalent labeling or cross-linking, incorporate labels to improve the ionization or dissociation of characteristic peptides in complex mixtures, and affinity-enrich various poorly abundant protein translational modifications (PTMs). A chemical modification reaction needs to be simple and efficient for use in proteomics analysis, and should be performed without any complicated process for preparing the labeling reagent.

View Article and Find Full Text PDF

The nonthermal destruction of aqueous film-forming foam (AFFF) stockpiles, one of the major culprits responsible for water and soil contamination by per- and polyfluoroalkyl substances (PFAS), is extremely challenging because of the coexistence of mixed recalcitrant PFAS and complicated organic matrices at extremely high concentrations. To date, the complete defluorination of undiluted AFFF at ambient conditions has not been demonstrated. This study reports a novel piezoelectric ball milling approach for treating AFFF with a total organic fluorine concentration of 9080 mg/L and total organic carbon of 234 g/L.

View Article and Find Full Text PDF

Key Clinical Message: Although the symptoms of accidental chlorine inhalation are typically mild, severe exposure can result in acute respiratory distress syndrome (ARDS). We present a case of pediatric ARDS due to chlorine exposure in which lung lavage and exogenous surfactant were successful in avoiding more invasive and costly treatments.

Abstract: Chlorine inhalation as a result of swimming pool chlorination accidents is relatively common.

View Article and Find Full Text PDF

Objectives: Re-operations due to material degeneration carry a burden for patients with congenital heart disease (CHD). The study aim was to compare rapid vs. slow degeneration of biomaterials in CHD patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!