Probing the photonic density of states using layer-by-layer self-assembly.

Opt Lett

The Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, USA.

Published: June 2012

The process of spontaneous emission can be dramatically modified by optical microstructures and nanostructures. We have studied the modification of fluorescence dynamics using a variable thickness polymer spacer layer fabricated using layer-by-layer self-assembly with nanometer accuracy. The change in fluorescence lifetime with spacer layer thickness agrees well with theoretical predictions based on the modified photonic density of states (PDOS), and yields consistent values for the fluorophores' intrinsic fluorescence lifetime and quantum yield near a dielectric as well as a plasmonic interface. Based on this observation, we further demonstrate that self-assembled fluorophores can be used to probe the modified PDOS near optical microstructures and nanostructures.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.37.001835DOI Listing

Publication Analysis

Top Keywords

photonic density
8
density states
8
layer-by-layer self-assembly
8
optical microstructures
8
microstructures nanostructures
8
spacer layer
8
fluorescence lifetime
8
probing photonic
4
states layer-by-layer
4
self-assembly process
4

Similar Publications

This study presents a comprehensive investigation into the intrinsic properties of RNiP (where R = Sm, Eu) filled skutterudite, employing the full-potential linearized augmented plane wave method within density functional theory (DFT) simulations using the WIEN2k framework. Structural, phonon stability, mechanical, electronic, magnetic, transport, thermal, and optical properties are thoroughly explored to provide a holistic understanding of these materials. Initially, the structural stability of SmNiP and EuNiP is rigorously evaluated through ground-state energy calculations obtained from structural optimizations, revealing a preference for a stable ferromagnetic phase over competing antiferromagnetic and non-magnetic phases.

View Article and Find Full Text PDF

This paper presents progress made toward the overarching goal to adapt single-photon-counting microcalorimeters to magnetic fusion energy research and demonstrate the value of such measurements for fusion. Microcalorimeter spectrometers combine the best characteristics of x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and broad spectral coverage sufficient to measure impurity species from Be to W. As a proof-of-principle experiment, a NASA-built x-ray microcalorimeter spectrometer has been installed on the Madison Symmetric Torus (MST) at the Wisconsin Plasma Physics Laboratory.

View Article and Find Full Text PDF

Introduction: Diabetes mellitus (DM) is a chronic metabolic disorder that increases fragility fracture risk. Conventional DXA-based areal bone mineral density (aBMD) assessments often underestimate this risk. Cortical Backscatter (CortBS) ultrasound, a radiation-free technique, non-invasively analyzes cortical bone's viscoelastic and microstructural properties.

View Article and Find Full Text PDF

Purpose: To assess bone mineral density (BMD) in middle-aged individuals in Shanghai, in order to improve awareness of osteopenia and osteoporosis screening.

Methods: The clinical data of 1107 permanent residents of Shanghai aged 40-60 years were collected using a random cluster sampling method. Osteoporosis questionnaire survey and BMD test were conducted.

View Article and Find Full Text PDF

Utility of photon-counting detectors for MV-kV dual-energy computed tomography imaging.

J Med Imaging (Bellingham)

December 2024

University of Chicago, Department of Radiology, Chicago, Illinois, United States.

Purpose: High soft-tissue contrast imaging is essential for effective radiotherapy treatment. This could potentially be realized using both megavoltage and kilovoltage x-ray sources available on some therapy treatment systems to perform "MV-kV" dual-energy (DE) computed tomography (CT). However, noisy megavoltage images obtained with existing energy-integrating detectors (EIDs) are a limiting factor for clinical translation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!