Lag screw fixation of fracture of the anterior mandible: a new minimal access technique.

J Maxillofac Oral Surg

Government Dental College and Hospital, Ayurvedic College Campus, G.E. Road, Raipur, 492001 Chhattisgarh India.

Published: June 2011

Objective: Purpose of this study to introduce a new minimal access technique for management of anterior mandible fracture with several advantages over conventional methods.

Method: Four cases of undisplaced anterior mandibular fracture were selected. Tension band was achieved either by arch bar fixation to mandible or placement of interdental wire followed by intermaxillary fixation. With a 1 cm vertical incision was placed adjacent to fractured line. Fractured segment was immobilized with lag screw with minimal stripping. All patients were followed for 6 months.

Results: All four cases shown good stable segment after 6 months of post operative follow up. OPG revealed well placed lag screw and there were no surgical complications, for example parasthesia, scarring and odema.

Conclusion: Fixation of anterior mandible fracture using this technique can achieve good stability and appropriate compression. The technique is simple and easily performed, reducing the surgical time, reduce the chances of infection due to less exposure and promote the healing process by producing stress in the fracture lines.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3177514PMC
http://dx.doi.org/10.1007/s12663-011-0176-2DOI Listing

Publication Analysis

Top Keywords

lag screw
12
anterior mandible
12
minimal access
8
access technique
8
mandible fracture
8
fracture
5
fixation
4
screw fixation
4
fixation fracture
4
anterior
4

Similar Publications

Objectives: To compare lag-screw slide and revision surgery rate between two generations of the Stryker Gamma cephalomedullary nail (Stryker, Kalamazoo, MI).

Methods: Design: Retrospective chart review.

Setting: Single academic, Level-1 Trauma Center.

View Article and Find Full Text PDF

Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.

View Article and Find Full Text PDF

Objective: Despite several surgical options, there has yet to be a consensus on the best treatment for femoral neck fracture (FNF) due to higher complication rates compared to other bone fractures. This study aims to examine the possible consequences and solution suggestions of changing screws during surgery for various reasons in FNF surgical treatment from a biomechanical perspective.

Method: FNF and treatment materials were analyzed biomechanically using a package program based on the finite element method (FEM).

View Article and Find Full Text PDF

Background: This study aimed to analyze the files of patients treated using PFN-A or INTERTAN intramedullary nails to reveal additional superiorities or disadvantageous factors for selecting the better intramedullary fixation method in patients presenting with intertrochanteric femur fractures.

Methods: In this retrospective study, the files of the patients who were operated on for intertrochanteric femur fractures using intramedullary fixation methods between September 2010 and June 2015 in the Orthopedics and Traumatology Clinic, Çukurova University Faculty of Medicine, were reviewed. The data including age, gender, chronic diseases, causes of fractures, fracture classification based on Arbeitsgemeinschaft für Osteosynthesefragen (AO), the nail type (long or short), the interval between trauma and surgery, duration of anesthesia and surgery, hospitalization duration, amount of blood transfusion, the Tip-Apex Distance (TAD) in postoperative radiographs, functional outcomes according to Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), postoperative complications, need for revision, and mortality was noted.

View Article and Find Full Text PDF

Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!