Background: Expiratory time constants are used to quantify emptying of the lung as a whole, and emptying of individual lung compartments. Breathing low-density helium/oxygen mixtures may modify regional time constants so as to redistribute ventilation, potentially reducing gas trapping and hyperinflation for patients with obstructive lung disease. In the present work, bench and mathematical models of the lung were used to study the influence of heterogeneous patterns of obstruction on compartmental and whole-lung time constants.
Methods: A two-compartment mechanical test lung was used with the resistance in one compartment held constant, and a series of increasing resistances placed in the opposite compartment. Measurements were made over a range of lung compliances during ventilation with air or with a 78/22% mixture of helium/oxygen. The resistance imposed by the breathing circuit was assessed for both gases. Experimental results were compared with predictions of a mathematical model applied to the test lung and breathing circuit. In addition, compartmental and whole-lung time constants were compared with those reported by the ventilator.
Results: Time constants were greater for larger minute ventilation, and were reduced by substituting helium/oxygen in place of air. Notably, where time constants were long due to high lung compliance (i.e. low elasticity), helium/oxygen improved expiratory flow even for a low level of resistance representative of healthy, adult airways. In such circumstances, the resistance imposed by the external breathing circuit was significant. Mathematical predictions were in agreement with experimental results. Time constants reported by the ventilator were well-correlated with those determined for the whole-lung and for the low-resistance compartment, but poorly correlated with time constants determined for the high-resistance compartment.
Conclusions: It was concluded that breathing a low-density gas mixture, such as helium/oxygen, can improve expiratory flow from an obstructed lung compartment, but that such improvements will not necessarily affect time constants measured by the ventilator. Further research is required to determine if alternative measurements made at the ventilator level are predictive of regional changes in ventilation. It is anticipated that such efforts will be aided by continued development of mathematical models to include pertinent physiological and pathophysiological phenomena that are difficult to reproduce in mechanical test systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3497861 | PMC |
http://dx.doi.org/10.1186/1475-925X-11-27 | DOI Listing |
Clin Pharmacokinet
January 2025
College of Pharmacy, Kyungsung University, 309, Suyeong-ro, Nam-gu, Busan, 48434, Republic of Korea.
Background And Objective: Telmisartan exhibits significant pharmacokinetic (PK) variability, but it remains unclear whether its PK profile is altered in hypertensive patients. This study aimed to characterize telmisartan PKs by conducting a meta-analysis and developing a pooled population PK model based on data from healthy subjects and hypertensive patients.
Methods: Relevant literature was identified by a systematic approach.
Parasitol Res
January 2025
HUN-REN Veterinary Medical Research Institute, 21, Hungária Krt, 1143, Budapest, Hungary.
The European catfish (Silurus glanis) is an important species with high economic value, and its growing demand has led to intensive farming practices for it. However, this species is increasingly challenged by parasitic infections, particularly from a specific gill monopisthocotylan parasite called Thaparocleidus vistulensis. To establish effective management strategies, it is crucial to comprehend the fundamental environmental variables that could influence the reproductive and survival behavior of T.
View Article and Find Full Text PDFArterial compliance (AC) is an important cardiovascular parameter characterizing mechanical properties of arteries. AC is significantly influenced by arterial wall structure and vasomotion, and it markedly influences cardiac load. A new method, based on a two-element Windkessel model, has been recently proposed for estimating AC as the ratio of the time constant T of the diastolic blood pressure decay and peripheral vascular resistance derived from clinically available stroke volume measurements and selected peripheral blood pressure parameters which are less prone to peripheral distortions.
View Article and Find Full Text PDFClin Pharmacol Ther
January 2025
Certara Predictive Technologies Division, Certara UK Limited, Sheffield, UK.
Understanding cytokine-related therapeutic protein-drug interactions (TP-DI) is crucial for effective medication management in conditions characterized by elevated inflammatory responses. Recent FDA and ICH guidelines highlight a systematic, risk-based approach for evaluating these interactions, emphasizing the need for a thorough mechanistic understanding of TP-DIs. This study integrates the physiologically based pharmacokinetic (PBPK) model for TP (specifically interleukin-6, IL-6) with small-molecule drug PBPK models to elucidate cytokine-related TP-DI mechanistically.
View Article and Find Full Text PDFChirality
January 2025
JASCO Corporation, Japan.
A vibrational circular dichroism (VCD) instrument having a thermoelectrically cooled detector (denoted as a TEC unit) was constructed in this study. An electronic device, instead of liquid nitrogen, was employed in the instrument to cool the detector. The feasibility of the system was examined by recording the VCD spectra of liquid pinenes and insect wings.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!