The ICRP/ICRU adult male reference voxel phantom incorporated in Monte Carlo code FLUKA is used for estimating specific absorbed fractions (SAFs) for photons due to the presence of internal radioactive contamination in the human respiratory tract (RT). The compartments of the RT, i.e. extrathoracic (ET1 and ET2) and thoracic (bronchi, bronchioles, alveolar interstitial) regions, lymph nodes of both regions and lungs are considered as the source organs. The nine organs having high tissue weighting factors such as colon, lungs, stomach wall, breast, testis, urinary bladder, oesophagus, liver and thyroid and the compartments of the RT are considered as target organs. Eleven photon energies in the range of 15 keV to 4 MeV are considered for each source organ and the computed SAF values are presented in the form of tables. For the target organs in the proximity of the source organ including the source organ itself, the SAF values are relatively higher and decrease with increase in energy. As the distance between source and target organ increases, SAF values increase with energy and reach maxima depending on the position of the target organ with respect to the source organ. The SAF values are relatively higher for the target organs with smaller masses. Large deviations are seen in computed SAF values from the existing MIRD phantom data for most of the organs. These estimated SAF values play an important role in the estimation of equivalent dose to various target organs of a worker due to intake by inhalation pathway.