A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Toxicity assessment of extracts from infusion sets in cEND brain endothelial cells. | LitMetric

In vitro safety assessment of disposable medical devices, including infusion sets, is usually performed using L-929 mouse keratinocytes. However, cells of different origin (endothelial, lymphoid and myeloid cells) are also exposed to infusion sets' extractables during their clinical use. We studied whether the cEND mouse brain endothelial cells can be suitable for in vitro safety assessment of infusion sets. We analyzed infusion sets from different manufacturers that varied in design and storage time. cEND cells were incubated with extracts of individual parts of the infusion sets (tube, cup, latex), and relative toxicities were analyzed using MTT test, DCFH-DA-based analysis of reactive oxygen species formation, apoptosis and cell cycle analyses. We identified a pattern of yellowing of the infusion sets upon storage and revealed that it originated from the latex part. Extracts of the individual parts of the infusion sets, primarily of the latex, were toxic to the cEND cells leading to induction of apoptosis and cell death. We conclude that infusion sets release extractables that can be toxic to the endothelial cells of the patients that receive infusion. We suggest to use cEND cells for in vitro safety assessment of infusion sets and other medical devices that release extractables to the bloodstream.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2012.05.019DOI Listing

Publication Analysis

Top Keywords

infusion sets
36
endothelial cells
12
vitro safety
12
safety assessment
12
cend cells
12
infusion
11
sets
9
brain endothelial
8
cells
8
cells vitro
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!