Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams.

Phys Med Biol

Radiation Medicine Program, Princess Margaret Hospital and Department of Radiation Oncology, University of Toronto, Toronto, ON, M5G 2M9, Canada.

Published: June 2012

This study examines variations of bone and mucosal doses with variable soft tissue and bone thicknesses, mimicking the oral or nasal cavity in skin radiation therapy. Monte Carlo simulations (EGSnrc-based codes) using the clinical kilovoltage (kVp) photon and megavoltage (MeV) electron beams, and the pencil-beam algorithm (Pinnacle(3) treatment planning system) using the MeV electron beams were performed in dose calculations. Phase-space files for the 105 and 220 kVp beams (Gulmay D3225 x-ray machine), and the 4 and 6 MeV electron beams (Varian 21 EX linear accelerator) with a field size of 5 cm diameter were generated using the BEAMnrc code, and verified using measurements. Inhomogeneous phantoms containing uniform water, bone and air layers were irradiated by the kVp photon and MeV electron beams. Relative depth, bone and mucosal doses were calculated for the uniform water and bone layers which were varied in thickness in the ranges of 0.5-2 cm and 0.2-1 cm. A uniform water layer of bolus with thickness equal to the depth of maximum dose (d(max)) of the electron beams (0.7 cm for 4 MeV and 1.5 cm for 6 MeV) was added on top of the phantom to ensure that the maximum dose was at the phantom surface. From our Monte Carlo results, the 4 and 6 MeV electron beams were found to produce insignificant bone and mucosal dose (<1%), when the uniform water layer at the phantom surface was thicker than 1.5 cm. When considering the 0.5 cm thin uniform water and bone layers, the 4 MeV electron beam deposited less bone and mucosal dose than the 6 MeV beam. Moreover, it was found that the 105 kVp beam produced more than twice the dose to bone than the 220 kVp beam when the uniform water thickness at the phantom surface was small (0.5 cm). However, the difference in bone dose enhancement between the 105 and 220 kVp beams became smaller when the thicknesses of the uniform water and bone layers in the phantom increased. Dose in the second bone layer interfacing with air was found to be higher for the 220 kVp beam than that of the 105 kVp beam, when the bone thickness was 1 cm. In this study, dose deviations of bone and mucosal layers of 18% and 17% were found between our results from Monte Carlo simulation and the pencil-beam algorithm, which overestimated the doses. Relative depth, bone and mucosal doses were studied by varying the beam nature, beam energy and thicknesses of the bone and uniform water using an inhomogeneous phantom to model the oral or nasal cavity. While the dose distribution in the pharynx region is unavailable due to the lack of a commercial treatment planning system commissioned for kVp beam planning in skin radiation therapy, our study provided an essential insight into the radiation staff to justify and estimate bone and mucosal dose.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/57/12/3885DOI Listing

Publication Analysis

Top Keywords

electron beams
28
bone mucosal
16
mev electron
16
monte carlo
12
uniform water
12
skin radiation
8
radiation therapy
8
therapy monte
8
photon megavoltage
8
beams
8

Similar Publications

Nanomaterial properties such as size, structure, and composition can be controlled by manipulating radiation, such as gamma rays, X-rays, and electron beams. This control allows scientists to create materials with desired properties that can be used in a wide range of applications, from electronics to medicine. This use of radiation for nanotechnology is revolutionizing the way we design and manufacture materials.

View Article and Find Full Text PDF

The generation of laser-induced periodic surface structures (LIPSS) using femtosecond lasers facilitates the engineering of material surfaces with tailored functional properties. Numerous aspects of their complex formation process are still under debate, despite intensive theoretical and experimental research in recent decades. This particularly concerns the challenge of verifying approaches based on electromagnetic effects or hydrodynamic processes by experiment.

View Article and Find Full Text PDF

Scintillation screens are widely used to diagnose high-charge density, low-average current electron beams from laser wakefield accelerators (LWFAs). However, the absolute response between emitted photons and electron charge has only been calibrated at a limited number of facilities, and there have been discrepancies between these calibrations. In this report, we comprehensively revised the absolute charge calibration of two high relative brightness scintillating screens of LANEX Regular (Carestream) and PI200 (Mitsubishi) by employing the high-brightness photoinjector at the National Synchrotron Radiation Research Center (NSRRC), which provides electron beams with variable charges (50-350 pC per pulse) and energies (26.

View Article and Find Full Text PDF

This article establishes a physical model of the interaction between surface electron beams and plasma with a transverse magnetic field. The dispersion relationship between electron beam and transverse magnetized plasma interaction was derived using perturbation method and field matching method, respectively. We studied the effects of magnetic field, plasma density, electron beam density, and electron beam velocity on radiation frequency and bandwidth.

View Article and Find Full Text PDF

Enhancement of Harmonic Heating by Magnetized Plasma Series Resonance in Capacitive Radio Frequency Discharges.

Phys Rev Lett

December 2024

Key Laboratory of Materials Modification by Laser, Ion, and Electron Beams (Ministry of Education), School of Physics, Dalian University of Technology, Dalian 116024, People's Republic of China.

We present a novel resonance mode in capacitive radio frequency (rf) discharges in the presence of an oblique magnetic field at low pressures. We observe the self-excitation of high-frequency harmonics of the current in magnetized capacitive rf discharges through the magnetized plasma series resonance (MPSR) induced by applying a low-frequency power. Utilizing an equivalent circuit model, we reveal that these harmonics arise from the hybrid combination of the magnetic gyration of electrons and the PSR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!