Objective: The ideal hemostatic agent for treatment of suture-line bleeding at vascular anastomoses has not yet been established. This study evaluated whether the use of a fibrin sealant containing 500 IU/mL thrombin and synthetic aprotinin (FS; marketed in the United States under the name TISSEEL) is beneficial for treatment of challenging suture-line bleeding at vascular anastomoses of expanded polytetrafluoroethylene (ePTFE) grafts, including those further complicated by concomitant antiplatelet therapies.
Methods: Over a 1-year period ending in 2010, ePTFE graft prostheses, including arterio-arterial bypasses and arteriovenous shunts, were placed in 140 patients who experienced suture-line bleeding that required treatment after completion of anastomotic suturing. Across 24 US study sites, 70 patients were randomized and treated with FS and 70 with manual compression (control). The primary end point was the proportion of patients who achieved hemostasis at the study suture line at 4 minutes after start of application of FS or positioning of surgical gauze pads onto the study suture line.
Results: There was a statistically significant difference in the comparison of hemostasis rates at the study suture line at 4 minutes between FS (62.9%) and control (31.4%) patients (P < .0001), which was the primary end point. Similarly, hemostasis rates in the subgroup of patients on antiplatelet therapies were 64.7% (FS group) and 28.2% (control group). When analyzed by bleeding severity, the hemostatic advantage of FS over control at 4 minutes was similar (27.8% absolute improvement for moderate bleeding vs 32.8% for severe bleeding). Logistic regression analysis (accounting for gender, age, intervention type, bleeding severity, blood pressure, heparin coating of ePTFE graft, and antiplatelet therapies) found a statistically significant treatment effect in the odds ratio (OR) of meeting the primary end point between treatment groups (OR, 6.73; P < .0001), as well as statistically significant effects for intervention type (OR, 0.25; P = .0055) and bleeding severity (OR, 2.59; P = .0209). The safety profile of FS was excellent as indicated by the lack of any related serious adverse events.
Conclusions: The findings from this phase 3 study confirmed that FS is safe and its efficacy is superior to manual compression for hemostasis in patients with peripheral vascular ePTFE grafts. The data also suggest that FS promotes hemostasis independently of the patient's own coagulation system, as shown in a representative population of patients with vascular disease under single- or dual-antiplatelet therapies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvs.2012.01.009 | DOI Listing |
J Contemp Dent Pract
September 2024
Department of Prosthodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Sangli, Maharashtra, India, ORCID: https://orcid.org/0000-0002-6661-0931.
Aim: The aim of this systematic review was to evaluate the effect of build orientation on the mechanical and physical properties of additively manufactured resin using digital light processing (DLP).
Background: The properties of 3D-printed materials are influenced by various factors, including the type of additive manufacturing (AM) system and build orientation. There is a scarcity of literature on the effect of build orientation on the mechanical and physical properties of additively manufactured resins using DLP technology in dentistry.
Ann Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.
Cardiovasc Intervent Radiol
January 2025
Department of Vascular and Endovascular Surgery, The Affiliated Suzhou Hospital of Nanjing Medical University, 242 Guangji Road, Gusu District, Suzhou, 215000, China.
Purpose: To describe the downsizing post-closure technique for access hemostasis during emergency endovascular repair (EVAR) in ruptured abdominal aortic aneurysms (RAAA).
Materials And Methods: A cohort of eight patients underwent emergency EVAR through 16 femoral access sites for infrarenal RAAA. The downsizing post-closure technique, which involves a reduction in the size of the large-bore access by advancing a 10F sheath, was consistently applied.
J Appl Physiol (1985)
January 2025
Department of Kinesiology and Health Sciences, University of Waterloo, Waterloo, Canada.
Measurement of blood flow during exercise is crucial for understanding physiological responses and performance outcomes. However, traditional methods are often invasive, costly, or require substantial training, limiting widespread research in this area. This study introduces the innovative use of limb-affixed ultrasound probe holders for vascular imaging during exercise to overcome these challenges.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!