[Ballistic quality assurance].

Cancer Radiother

Unité de radiophysique et de radioprotection des hôpitaux de Toulouse, Hôtel Dieu Saint-Jacques, 2 rue Viguerie,Toulouse cedex 9, France.

Published: June 2012

This review describes the ballistic quality assurance for stereotactic intracranial irradiation treatments delivered with Gamma Knife® either dedicated or adapted medical linear accelerators. Specific and periodic controls should be performed in order to check the mechanical stability for both irradiation and collimation systems. If this step remains under the responsibility of the medical physicist, it should be done in agreement with the manufacturer's technical support. At this time, there are no recent published guidelines. With technological developments, both frequency and accuracy should be assessed in each institution according to the treatment mode: single versus hypofractionnated dose, circular collimator versus micro-multileaf collimators. In addition, "end-to-end" techniques are mandatory to find the origin of potential discrepancies and to estimate the global ballistic accuracy of the delivered treatment. Indeed, they include frames, non-invasive immobilization devices, localizers, multimodal imaging for delineation and in-room positioning imaging systems. The final precision that could be reasonably achieved is more or less 1mm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.canrad.2011.06.007DOI Listing

Publication Analysis

Top Keywords

[ballistic quality
4
quality assurance]
4
assurance] review
4
review describes
4
describes ballistic
4
ballistic quality
4
quality assurance
4
assurance stereotactic
4
stereotactic intracranial
4
intracranial irradiation
4

Similar Publications

Quantum Dynamics Simulations of Exciton Polariton Transport.

Nano Lett

January 2025

Department of Chemistry, University of Rochester, Rochester, New York 14627, United States.

Recent experiments have shown that exciton transport can be significantly enhanced through hybridization with confined photonic modes in a cavity. The light-matter hybridization generates exciton-polariton (EP) bands, whose group velocity is significantly larger than the excitons. Dissipative mechanisms that affect the constituent states of EPs, such as exciton-phonon coupling and cavity loss, have been observed to reduce the group velocities in experiments.

View Article and Find Full Text PDF

Virtual Frisch grid perovskite CsPbBr semiconductor with 2.2-centimeter thickness for high energy resolution gamma-ray spectrometer.

Nat Commun

January 2025

State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou, China.

High intrinsic detection efficiency is as decisive as high energy resolution. Scaling up detector volume has presented great challenges, preventing perovskite semiconductors from reaching sufficient detection efficiency. We report a hole-only virtual-Frisch-grid CsPbBr detector up to 2.

View Article and Find Full Text PDF

Objectives: To report outcomes and risk factors of complications following low-velocity ballistic fractures of the femur.

Design: Retrospective case series.

Setting: Academic Level I trauma center.

View Article and Find Full Text PDF

Time-of-flight (TOF) based underwater imaging is of great importance in practical applications due to its high image quality. Existing works separate scattered and ballistic photons in the time and space domains to recover objects in weakly scattered underwater scenes. However, in turbid underwater environments, absorption and strong anisotropic scattering cause weak ballistic light tightly coupled with forward-scattered and backward-scattered photons.

View Article and Find Full Text PDF

We present a novel, to the best of our knowledge, approach to overcome the limitations imposed by scattering media using time-gated light field tomography. By integrating the time-gating technique with light field imaging, we demonstrate the ability to capture and reconstruct images with different depths through highly scattering environments. Our method exploits the temporal characteristics of light propagation to selectively isolate ballistic photons, enabling enhanced depth resolution and improved imaging quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!