Cardiac troponins (cTn) are the preferred markers for the diagnosis of acute myocardial infarction (AMI). The guidelines recommend the use of the 99th percentile upper reference concentration of a healthy population as the diagnostic cut-off for AMI. However, a broad range of upper reference limits is still employed, complicating the diagnosis of AMI. This overview is meant to assist laboratory specialists to define an appropriate cut-off value for the diagnosis of AMI. Therefore, we provide an overview of the analytical performance and upper reference limits of seven (high-)sensitivity cTn assays: Roche high-sensitivity cTnT and ADVIA Centaur, Stratus CS, Dimension Vista, Vitros ECi, Access and Architect cTnI assays. It is shown that none of the reference populations completely met the guidelines, including those in package inserts. Forty percent of the studies collected less than the advised minimum of 300 subjects. Many studies (50%) did not report their inclusion criteria, while lower 99th percentile limits were observed when more stringent selection criteria were applied. Higher troponin cut-offs were found in men and elderly subjects, suggesting sex- and age-specific cut-offs would be considered. Therefore, there is still need for a large, rigorously screened reference population to more accurately establish cTn upper reference limits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/cclm-2011-0895 | DOI Listing |
Blood Press Monit
January 2025
Shijiazhuang People's Hospital, Shijiazhuang, Hebei Province, China.
This study evaluates the measurement accuracy of the Hanvon FY730 upper-arm blood pressure (BP) monitor, which uses the Korotkoff sound method, in compliance with the AAMI/ESH/ISO universal standard (ISO 81060-2:2018). A clinical trial involving 86 eligible adults was conducted, and data were analyzed based on standardized protocols. The mean differences between the device and reference measurements for systolic blood pressure (SBP) and diastolic blood pressure (DBP) were -0.
View Article and Find Full Text PDFBlood Press Monit
December 2024
Institute for Pharmacology and Preventive Medicine, Cloppenburg, Germany.
Background: Accurate measurement of blood pressure (BP) is crucial for the diagnosis and ongoing management of hypertension. Only devices that have been validated using an established protocol should be used to measure BP. The aim of this study was to validate the Microlife BP3T01-1B, an automated upper-arm BP measuring device, according to the DIN EN ISO 81060-2:2018-11 (ANSI/AAMI/ISO 81060-2:2018) standard protocol.
View Article and Find Full Text PDFRhinology
January 2025
Kuopio, Finland.
Chronic rhinosinusitis with nasal polyps (CRSwNP), asthma, and non-steroidal anti-inflammatory drug-exacerbated respiratory disease (N-ERD) frequently coexist, forming a complex multimorbid condition often referred to as "global airway disease." This concept reflects shared pathophysiological mechanisms of eosinophilic inflammation and underscores the need for integrated treatment strategies targeting both upper and lower airway manifestations (1). The burden of severe CRSwNP, asthma, and N-ERD is substantial, particularly in terms of reduced quality of life, recurrent exacerbations, revision endoscopic sinus surgeries (ESS), and healthcare utilization (2).
View Article and Find Full Text PDFTransl Lung Cancer Res
December 2024
Division of Pulmonology, Allergy and Critical Care Medicine, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea.
Background: Despite the importance of early diagnosis of lung cancer and wide availability of chest radiography, the detection of operable stage lung cancer on chest radiographs (CXRs) remains challenging. This study aimed to investigate the effectiveness of artificial intelligence (AI)-based CXR analysis for detecting operable lung cancers.
Methods: Patients who underwent lung cancer surgery at two referral hospitals between March 2020 and February 2021 were retrospectively included in this study.
To promote the coordinated and sustainable development of hydropower exploitation and ecological environment in the upper reaches of the Yellow River, a fine simulation of the downstream riverway of Yangqu Hydropower Station was carried out to analyze the impact of the changes in water depth and flow velocity on fish habitats after the impoundment of Yangqu Hydropower Station. In this paper, was selected as the target fish species. The fish habitat model was constructed using MIKE21.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!