Conductive polymer composites, typically fabricated from a mix of conductive fillers and a polymer substrate, are commonly applied as bipolar plates in a fuel cell stack. Electrical conductivity is a crucial property that greatly depends on the distribution and orientation of the fillers. In this study, a 50-MHz ultrasound imaging system and analysis techniques capable of nondestructively assessing the properties of carbon fibers (CFs) in conductive polymer composites were developed. Composite materials containing a mix of polycarbonate substrates and 0 to 0.3 wt% of CFs were prepared using an injection molding technique. Ultrasonic A-line signals and C-scan images were acquired from each composite sample in regions at a depth of 0.15 mm beneath the sample surface (region A) and those at a depth of 0.3 mm (region B). The integrated backscatter (IB) and the Nakagami statistical parameter were calculated to quantitatively assess the samples. The area ratio, defined as the percentage of areas composed of CF images normalized by that of the whole C-scan image, was applied to further quantify the orientation of CFs perpendicular to the sample surface. Corresponding to the increase in CF concentrations from 0.1 to 0.3 wt%, the average IB and Nakagami parameter (m) of the composite samples increased from -78.10 ± 2.20 (mean ± standard deviation) to -72.66 ± 1.40 dB and from 0.024 ± 0.012 to 0.048 ± 0.011, respectively. The corresponding area ratios were respectively estimated to be 0.78 ± 0.35%, 2.33 ± 0.66%, and 2.20 ± 0.60% in region A of the samples; those of CFs with a perpendicular orientation were 0.04 ± 0.03%, 0.08 ± 0.02%, and 0.12 ± 0.05%. The area ratios in region B of the samples were calculated to be 1.19 ± 0.54%, 2.81 ± 0.42%, and 2.64 ± 0.76%, and those of CFs with a perpendicular orientation were 0.07 ± 0.04%, 0.12 ± 0.04%, and 0.14 ± 0.03%. According to the results of the orientations and ultrasonic images, CFs tended to distribute more uniformly in the deeper regions of the samples. This study validates that the distribution and orientation of CFs in conductive polymer composites could be sensitively and quantitatively assessed by high-frequency ultrasound in conjunction with current analysis methods.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2012.2282DOI Listing

Publication Analysis

Top Keywords

conductive polymer
16
polymer composites
12
cfs perpendicular
12
carbon fibers
8
high-frequency ultrasound
8
distribution orientation
8
cfs conductive
8
sample surface
8
orientation cfs
8
area ratios
8

Similar Publications

The composition of the metal-polymer friction pair is carefully considered for interacting with water and hydrogen, ensuring the metals electrode process potential remains below waters in a neutral medium. Simultaneously, adherence to defined chemical composition ratios for the metal-polymer materials is crucial. This analysis is conducted under conditions of thermal stabilization, characterized by a minimal temperature gradient across the rim thickness within an equivalent thermal field.

View Article and Find Full Text PDF

Cancer-associated fibroblasts (CAFs) are a crucial component in the tumor microenvironment (TME) of peritoneal metastasis (PM), where they contribute to tumor progression and metastasis via secretion of interleukin-6 (IL-6). Here, we investigated the role of IL-6 in PM of gastric cancer (GC) and assessed whether anti-IL-6 receptor antibody (anti-IL-6R Ab) could inhibit PM of GC. We conducted immunohistochemical analysis of IL-6 and α-smooth muscle (α-SMA) expressions in clinical samples of GC and PM, and investigated the interactions between CAFs and GC cells in vitro.

View Article and Find Full Text PDF

Pathogenic intracellular bacteria pose a significant threat to global public health due to the barriers presented by host cells hindering the timely detection of hidden bacteria and the effective delivery of therapeutic agents. To address these challenges, we propose a tandem diagnosis-guided treatment paradigm. A supramolecular sensor array is developed for simple, rapid, accurate, and high-throughput identification of intracellular bacteria.

View Article and Find Full Text PDF

Passive Radiant Cooling and Heating are green and sustainable methods of radiant heat management without consuming additional energy. However, the absorption of sunlight and poor insulation of materials can reduce radiative cooling and also affect radiative heating performance. Herein, we have constructed porous hierarchical dual-mode silk nanofibrous aerogel (SNF) films with high mechanical toughness and stability using silk nanofibers/GO.

View Article and Find Full Text PDF

The development of electrode materials for aqueous ammonium-ion supercapacitors (NH-SCs) has garnered significant attention in recent years. Poor intrinsic conductivity, sluggish electron transfer and ion diffusion kinetics, as well as structural degradation of vanadium oxides during the electrochemical process, pose significant challenges for their efficient ammonium-ion storage. In this work, to address the above issues, the core-shell VO·nHO@poly(3,4-ethylenedioxithiophene) composite (denoted as VOH@PEDOT) is designed and prepared by a simple agitation method to boost the ammonium-ion storage of VO·nHO (VOH).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!