Objective: To obtain images of anterior and posterior segments of the eye using a slit-lamp (SL)/spectral domain (SD) optical coherence tomography (OCT) integrated system designed for the human eye, in the cat, dog, minipig and monkey.

Animals Studied: One healthy adult monkey, one healthy adult minipig, one healthy adult dog, one healthy adult cat, and three cats and four dogs affected by corneal or retinal diseases.

Procedure: A SL SCAN-1 SD-OCT, which is a slit-lamp SL-D7 that contains an integrated OCT module and a fundus viewer, was used to generate OCT images (512-2048), while simultaneously taking 'en-face' slit-lamp images (efSL). OCT images were obtained under sedation or anesthesia. These images were compared to histological retinal sections obtained from a monkey, a minipig, a dog, and a cat.

Results: 'en-face' slit-lamp images and OCT images of the ocular tissues were obtained allowing for the identification of different corneal and retinal layers in all animal species. Measurements of the total retinal thickness (TRT) from the inner limiting membrane to the retinal pigment epithelium were performed in various regions throughout the retina. Reduction in TRT was consistent with clinical features of retinal degeneration identified in dogs and cats.

Conclusion: This noninvasive procedure is useful for both experimental and clinical assessments of ocular tissue damage. Images of anterior and posterior segments are readily obtained under routine clinical conditions. Future studies are warranted to establish normal OCT data in our patients with this new instrument.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1463-5224.2012.01037.xDOI Listing

Publication Analysis

Top Keywords

healthy adult
16
anterior posterior
12
oct images
12
images
9
animal species
8
images anterior
8
posterior segments
8
corneal retinal
8
'en-face' slit-lamp
8
slit-lamp images
8

Similar Publications

Perfusion Capacity as a Predictive Index for Assessing Visual Functional Recovery in Patients With Idiopathic Epiretinal Membrane.

Transl Vis Sci Technol

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.

Purpose: This study investigates the association between visual function and retinal vasculature metrics, particularly perfusion capacity (PC), in eyes with idiopathic epiretinal membrane (iERM), using optical coherence tomography angiography (OCTA).

Methods: This retrospective study includes 30 eyes from 30 iERM patients who had surgery, with a three-month follow-up period. In addition, 28 eyes from 28 healthy individuals served as a control group.

View Article and Find Full Text PDF

Background: Patient Reported Outcomes Measurement Information System Fatigue Short-Form (PROMIS-F-SF) is a self-administered, patient reported outcome (PRO) designed to assess fatigue in healthy and clinical populations and for tracking progress during treatment for disorders complicated with fatigue.

Methods: Patients in the Mental Health Service Outpatient Clinics and healthy volunteers were invited to complete a survey, which included the Danish translation of the PROMIS-F-SF, the Chalder Fatigue Scale (CFS-11), and measures of depression and anxiety. We conducted a confirmatory factor analysis of the previously suggested single-factor structure of the instrument.

View Article and Find Full Text PDF

Evaluation of variations in predominant gut microbiota members in inflammatory bowel disease using real-time PCR.

Mol Biol Rep

January 2025

Department of Internal Medicine, Faculty of Medicine, Urmia University of Medical Sciences, Imam Khomeini Hospital, Urmia, Iran.

Inflammatory Bowel Disease (IBD) is a persistent ailment that impacts many individuals worldwide. The interaction between the immune system and gut microbiome is thought to influence IBD development. This study aimed to assess some microbiota in IBD patients compared to healthy individuals.

View Article and Find Full Text PDF

Voxel-based morphometry (VBM) of T1-weighted (T1-w) magnetic resonance imaging (MRI) is primarily used to study the association of brain structure with cognitive functions. However, in theory, T2-weighted (T2-w) MRI could also be used in VBM studies because of its sensitivity to pathology and tissue changes. We aimed to compare the T1-w and T2-w images to study brain structures in association with cognitive abilities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!