Background: The best storage temperature in liver transplantation remains an unsolved question.

Methods: After storage for 24h in University of Wisconsin solution at +4°C, +1°C, or -0.5°C, rat livers were subjected, or not, to 15min of warm ischemia, rinsed with Ringer lactate, and subsequently reperfused with oxygenated Krebs-Henseleit buffer.

Results: In the presence of warm ischemia, for livers stored at +4°C, creatine kinase (CK) peaked at 21±5IUg(-1)h(-1), hepatic resistance at 34,700±1500dynscm(-5), bile flow reached 18±4μLg(-1)h(-1) after 10min, and oxygen consumption stabilized at about 25μmolg(-1)h(-1) after 20min. When livers were stored at +1°C, CK and hepatic resistance were lowered, bile production was 33±6μLg(-1)h(-1) (P<0.05 versus +4°C), and oxygen consumption was 105±10μmolg(-1)h(-1) (P<0.001). For livers stored at-0.5°C, results were not statistically different from those of the +1°C group except for bile flow, which was significantly lower. Without warm ischemia, the peak of CK (P=0.015) and the peak hepatic resistance (P<0.001) of the +4°C group were significantly increased compared with the +1°C or -0.5°C groups. However, no difference in bile flow or oxygen consumption was observed. The number of trypan blue-positive nonparenchymal cells (P=0.003) and the gain in liver weight during the reperfusion (P=0.015) were minimal after storage at +1°C.

Conclusions: Static storage at +1°C improved liver function compared with +4°C or -0.5°C. Main beneficial effect was observed with parameters reflecting sinusoidal cells injury.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jss.2012.04.046DOI Listing

Publication Analysis

Top Keywords

warm ischemia
8
livers stored
8
hepatic resistance
8
best temperature
4
temperature static
4
static liver
4
liver graft
4
graft storage
4
storage 1°c
4
1°c background
4

Similar Publications

Background: We aimed to investigate the outcome of patients after RDN at different time points.

Methods: We studied the outcomes of 77 living robotic living donor nephrectomies (RDN). Donors were separated into three groups: learning curve period (LCP), stabilisation period (SP), and teaching period (TP).

View Article and Find Full Text PDF

Objective: To assess the efficacy of renal score grading in guiding therapy decisions, predicting perioperative outcomes, and characterising tumours following partial nephrectomy.

Methods: The retrospective, single-centre study was conducted at the University College Hospital Galway, Ireland, and comprised data from January 11, 2012, to June 17, 2016, of all patients aged >18 years who underwent partial nephrectomy as part of treatment for kidney cancer. Data was analysed using SPSS 20.

View Article and Find Full Text PDF

Introduction: The length of the right renal vein is a crucial vascular factor in kidney transplantation. Its shorter length compared to the left renal vein complicates venous anastomosis. The aim of this article is to review the literature on this topic and provide data from our experience.

View Article and Find Full Text PDF

Arsenic trioxide preconditioning attenuates hepatic ischemia- reperfusion injury in mice: Role of ERK/AKT and autophagy.

Chin Med J (Engl)

January 2025

Key Laboratory of Hepatosplenic Surgery, Ministry of Education, Department of Minimal Invasive Hepatic Surgery, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang 150001, China.

Background: Arsenic trioxide (ATO) is indicated as a broad-spectrum medicine for a variety of diseases, including cancer and cardiac disease. While the role of ATO in hepatic ischemia/reperfusion injury (HIRI) has not been reported. Thus, the purpose of this study was to identify the effects of ATO on HIRI.

View Article and Find Full Text PDF

Background: The Toumai MT-1000 Endoscopic Surgical System is a newly developed surgical robot from China. This study evaluates its feasibility, safety, and effectiveness for various urologic procedures based on our single-center experience.

Methods: From October 2023 to January 2024, 20 urologic procedures were performed at Peking University First Hospital using the Toumai MT-1000 system.

View Article and Find Full Text PDF