The diagnosis of a patent foramen ovale (PFO) is a dynamic process and it is based on the detection of blood shunting at the atrial level. Only under abnormal physiologic conditions, such as with a left ventricular assist device (LVAD), when right atrial pressure (RAP) exceeds left atrial pressure (LAP) the PFO may cause hypoxemia due to a right-to-left shunt. We report the closure of a PFO using a transcatheter approach in a patient on LVAD support.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8191.2012.01476.xDOI Listing

Publication Analysis

Top Keywords

patent foramen
8
foramen ovale
8
left ventricular
8
ventricular assist
8
assist device
8
atrial pressure
8
transcatheter closure
4
closure patent
4
ovale hypoxemia
4
hypoxemia left
4

Similar Publications

Pulmonary embolism (PE) and acute ischemic stroke (AIS) are serious conditions with high morbidity and mortality. In the USA, PE causes around 100,000 deaths annually, with higher incidence in males. AIS following PE occurs in 1-10% of cases and is a leading cause of death within 2 - 4 weeks post-stroke.

View Article and Find Full Text PDF

Background: Survival beyond one month of age is rare in children born with obstructed infracardiac total anomalous pulmonary venous connection (TAPVC). There are limited data available on surgical outcomes of the same subset. We conducted this retrospective study to identify risk factors associated with surgical outcomes in this patient population.

View Article and Find Full Text PDF

Patent foramen ovale: a variant of normal or a true congenital heart disease?

Cardiovasc Pathol

January 2025

Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua Medical School, Padova, Italy. Electronic address:

Foramen ovale plays a key role in foetal circulation, however it may remain patent after birth throughout the life. Its patency is so frequent in healthy people (27-35%), such as to be considered a variant of normal. It is at risk of complications, like paradoxical embolism by right to left shunt with stroke, migraine, temporary blindness, as well as aneurysm, thrombosis and endocarditis of the fossa ovalis.

View Article and Find Full Text PDF

We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!