Differences in measurements using cephalometry and thoracometry ante partum are reported. Two examiners performed fetal head and thorax measurements shortly after one another using the same ultrasonic equipment without knowing the measurements achieved by each other. A series of 195 measurements were made by a few less experienced examiners. The values measured showed a considerable scatter. The average difference between the biparietal head measurements was 2.23 mm, and the standard deviation of the differences of the values measured was 1.94 mm. In a further group of 175 fetuses the measurements were performed by two skilled examiners. For the diameter of the head there was an average measured difference of 1.38 mm and a standard deviation of the differences of 1.11 mm. For the average thorax diameter--corresponding to the arithmetical average from the straight and transverse diameter--the following results were achieved. 4.14 mm average difference of value measured an 3.41 mm standard deviation in the measuring run performed by less experienced ultrasonic examiners as opposed to 2.57 mm average difference and 1.74 mm standard deviation in the group of practised examiners. The average thorax diameter showed a considerably smaller scatter than the transverse thorax measurement on its own. The differences in the values measured could not be seen to be dependent on the gestational age.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-2007-1011557 | DOI Listing |
Acta Orthop
January 2025
Spine Unit, Department of Orthopaedic Surgery, Rigshospitalet, Copenhagen, Denmark.
Background And Purpose: Treatment of idiopathic scoliosis in childhood aims to prevent curve progression. It is generally accepted that curves > 50° have the highest risk of progression, but less well described is what happens with mild to moderate curves. The aim of this study was to assess long-term curve progression and health-related quality of life (HRQoL) and compare thoracic and thoracolumbar/lumbar (TL/L) curves.
View Article and Find Full Text PDFDrugs Aging
January 2025
Center for Clinical Management Research, VA Ann Arbor Healthcare System, NCRC 016-308E, 2800 Plymouth Rd, Ann Arbor, MI, 48109, USA.
Background: Central nervous system (CNS)-active polypharmacy (defined as concurrent exposure to three or more antidepressant, antipsychotic, antiseizure, benzodiazepine, opioid, or nonbenzodiazepine benzodiazepine receptor agonists) is associated with significant potential harms in persons living with dementia (PLWD).We conducted a pilot trial to assess a patient nudge intervention's implementation feasibility and preliminary effectiveness to prompt deprescribing conversations between PLWD experiencing CNS-active polypharmacy and their primary care clinicians ("clinicians").
Methods: We used the electronic health record to identify PLWD prescribed CNS-active polypharmacy in primary care clinics from two health systems.
Int J Comput Assist Radiol Surg
January 2025
Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA.
Purpose: Pulmonary perfusion imaging is a key lung health indicator with clinical utility as a diagnostic and treatment planning tool. However, current nuclear medicine modalities face challenges like low spatial resolution and long acquisition times which limit clinical utility to non-emergency settings and often placing extra financial burden on the patient. This study introduces a novel deep learning approach to predict perfusion imaging from non-contrast inhale and exhale computed tomography scans (IE-CT).
View Article and Find Full Text PDFMetabolomics
January 2025
Owlstone Medical Ltd., Cambridge, UK.
Introduction: Breath Volatile organic compounds (VOCs) are promising biomarkers for clinical purposes due to their unique properties. Translation of VOC biomarkers into the clinic depends on identification and validation: a challenge requiring collaboration, well-established protocols, and cross-comparison of data. Previously, we developed a breath collection and analysis method, resulting in 148 breath-borne VOCs identified.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Hebei Lansheng Bio-Tech Co, Ltd, Shijiazhuang, 052263, P. R. China.
A novel fluorescence sensing nanoplatform (CDs/AuNCs@ZIF-8) encapsulating carbon dots (CDs) and gold nanoclusters (AuNCs) within a zeolitic imidazolate framework-8 (ZIF-8) was developed for ratiometric detection of formaldehyde (FA) in the medium of hydroxylamine hydrochloride (NHOH·HCl). The nanoplatform exhibited pink fluorescence due to the aggregation-induced emission (AIE) effect of AuNCs and the internal filtration effect (IFE) between AuNCs and CDs. Upon reaction between NHOH·HCl and FA, a Schiff base formed via aldehyde-diamine condensation, releasing hydrochloric acid.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!