Objectives: The purpose of this study was to evaluate image quality and radiation dose using a prospectively electrocardiogram (ECG)-triggered axial scan protocol compared with standard retrospective ECG-gated helical scanning for coronary computed tomography angiography.
Background: Concerns have been raised regarding radiation exposure during coronary computed tomography angiography. Although the use of prospectively ECG-triggered axial scan protocols may effectively lower radiation dose compared with helical scanning, it is unknown whether image quality is maintained in a clinical setting.
Methods: In a prospective, multicenter, multivendor trial, 400 patients with low and stable heart rates were randomized to either an axial or a helical coronary computed tomography angiography scan protocol. The primary endpoint was to demonstrate noninferiority in image quality with the axial scan protocol, which was assessed on a 4-point scale (1 = nondiagnostic, 4 = excellent image quality). Secondary endpoints included radiation dose and the rate of downstream testing during 30-day follow-up.
Results: Image quality in patients scanned with the axial scan protocol (score 3.36 ± 0.59) was not inferior compared with helical scan protocols (3.37 ± 0.59) (p for noninferiority <0.004). Axial scanning was associated with a 69% reduction in radiation exposure (dose-length product [estimated effective dose] 252 ± 147 mGy · cm [3.5 ± 2.1 mSv] vs. 802 ± 419 mGy · cm [11.2 ± 5.9 mSv] for axial vs. helical scan protocols, p < 0.001). The rate of downstream testing did not differ (13.8% vs. 15.9% for axial vs. helical scan protocols, p = 0.555).
Conclusions: In patients with stable and low heart rates, the prospectively ECG-triggered axial scan protocol maintained image quality but reduced radiation exposure by 69% compared with helical scanning. Axial computed tomography data acquisition should be strongly recommended in suitable patients to avoid unnecessarily high radiation exposure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcmg.2011.12.017 | DOI Listing |
Eur Arch Otorhinolaryngol
January 2025
Department of Otolaryngology and Head and Neck Surgery, IRCSS AOU San Martino, University of Genoa, Largo Rosanna Benzi 10, 16132, Genoa, Italy.
Purpose: Immunoglobulin G4-related disease (IgG4-RD) is a complex systemic fibroinflammatory condition with different clinical manifestations affecting multiple organ systems. Despite its rarity, the disease presents diagnostic and therapeutic challenges due to its mimicry of malignancies and other immune-mediated disorders. The 2019 American College of Rheumatology/European League Against Rheumatism Classification Criteria for IgG4-Related Disease is the current state of art to confirm the diagnosis of IgG4-RD even in the absence of histological analysis.
View Article and Find Full Text PDFJ Fluoresc
January 2025
Department of Chemistry, The University of Burdwan, Golapbag, Burdwan, 713104, India.
Nitrogen doped Carbon Quantum Dots (NCQDs) have been synthesized using most economical and easiest hydrothermal process. Here, N-phenyl orthophenylenediamine and citric acid were utilised as a source of nitrogen and carbon for the preparation of NCQDs. The synthesized NCQDs were characterized using experimental techniques like UV - Vis absorption, FT-IR, transmission electron microscopy (TEM), X-ray Diffraction (XRD), EDX, dynamic light scattering (DLS), fluorimeter and time resolved fluorescence spectroscopy.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
January 2025
Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Ave, Wuhan, 430030, China.
Purpose: Since fibroblast activation protein (FAP), one predominant biomarker of cancer associated fibroblasts (CAFs), is highly expressed in the tumor stroma of various epidermal-derived cancers, targeting FAP for tumor diagnosis and treatment has shown substantial potentials in both preclinical and clinical studies. However, in preclinical settings, tumor-bearing mice exhibit relatively low absolute FAP expression levels, leading to challenges in acquiring high-quality PET images using radiolabeled FAP ligands (FAPIs) with low molar activity, because of which a saturation effect in imaging is prone to happen. Moreover, how exactly the molar dose of FAPI administered to a mouse influences the targeted PET imaging and radiotherapy remains unclear now.
View Article and Find Full Text PDFRadiol Phys Technol
January 2025
Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-ogu, Arakawa, Tokyo, 116-8551, Japan.
In plain radiography, scattered X-ray correction processing (Virtual Grid: VG) is used to estimate and correct scattered rays in images. We developed an objective evaluation system for bedside chest X-ray images using VG and investigated its usefulness. First, we trained the blind/referenceless image spatial quality evaluator (BRISQUE) on 200 images obtained by portable chest radiography.
View Article and Find Full Text PDFJ Wound Care
January 2025
Division of Plastic Surgery, Integrated Burn & Wound Care Center, Department of Surgery, Shuang-Ho Hospital, New Taipei City, Taiwan.
Objective: Deep sternal wound infection (DSWI) is a rare but devastating complication that is estimated to occur in 1-2% of patients after median sternotomy. Current standard of care (SoC) comprises antibiotics, debridement and negative pressure wound therapy (NPWT). Hyperbaric oxygen therapy (HBOT) appears to be an effective adjuvant therapy for osteomyelitis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!