Recent reports indicate the possible role of bladder CO(2) as a marker of low perfusion states. To test this hypothesis, shock was induced in six beagle dogs with 1 mg/kg of E. coli lipopolysaccharide, gastric CO(2) (CO(2)-G) was measured with a continuous monitor, and a pulmonary catheter was inserted in the bladder to measure CO(2) (CO(2)-B). Levels of CO(2)-B were found to be lower than those of CO(2)-G, with a mean difference of 36.8 mmHg (P < 0.001), and correlation between both measurements was poor (r(2) = 0.16). Even when the correlation between CO(2)-G and ΔCO(2)-G was narrow (r(2) = 0.86), this was not the case for the relationship between CO(2)-B and ΔCO(2)-B (r(2) = 0.29). Finally, the correlation between CO(2)-G and base deficit was good (r(2) = 0.45), which was not the case with the CO(2)-B correlation (r(2) = 0.03). In our experience, bladder CO(2) does not correlate to hemodynamic parameters and does not substitute gastric CO(2) for detection of low perfusion states.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3349138 | PMC |
http://dx.doi.org/10.1100/2012/360378 | DOI Listing |
Crit Care
December 2024
Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK.
Background: Entropy quantifies the level of disorder within a system. Low entropy reflects increased rigidity of homeostatic feedback systems possibly reflecting failure of protective physiological mechanisms like cerebral autoregulation. In traumatic brain injury (TBI), low entropy of heart rate and intracranial pressure (ICP) predict unfavorable outcome.
View Article and Find Full Text PDFJ Trauma Inj
December 2024
Department of Acute Care Surgery, Korea University Guro Hospital, Seoul, Korea.
Cardiac compression is the most crucial component of successful cardiopulmonary resuscitation (CPR). However, CPR procedure poses a risk of complications, even when CPR providers perform cardiac compressions as recommended. Reports indicate that solid organ injuries, including liver injuries, occur with an incidence of about 0.
View Article and Find Full Text PDFChin J Traumatol
December 2024
Beijing Key Lab of Regenerative Medicine in Orthopedics, Key Laboratory of Musculoskeletal Trauma and War Injuries PLA, Department of Orthopedics, The Fourth Medical Center, Chinese PLA General Hospital, Beijing, 100048, China. Electronic address:
Purpose: To investigate the protective effect of sub-hypothermic mechanical perfusion combined with membrane lung oxygenation on ischemic hypoxic injury of yorkshire brain tissue caused by traumatic blood loss.
Methods: This article performed a random controlled trial. Brain tissue of 7 yorkshire was selected and divided into the sub-low temperature anterograde machine perfusion group (n = 4) and the blank control group (n = 3) using the random number table method.
Eur J Intern Med
December 2024
Department of Critical Care Medicine, West China Hospital, Sichuan University, Chengdu, PR China. Electronic address:
Objectives: The purpose of this study was to determine whether our new thinking guidance named OPACCUS (oxygen metabolism, perfusion, arterial tension, cardiac output, systemic congestion, unregulated host response and search for inciting illness event) with 7 questions you need to ask before shock therapy and evidences provided by critical ultrasound considering hemodynamics, the unregulated host response and inciting illness event would improve mortality in shock patients.
Design: A multicenter, prospective, observational cohort study.
Setting: Intensive care units of 20 hospitals in Southwest China.
MAGMA
December 2024
Department of Radiology and Medical Informatics, Faculty of Medicine, University of Geneva, Geneva, Switzerland.
Objectives: Phosphorus-31 magnetic resonance spectroscopic imaging (P-MRSI) is a non-invasive tool for assessing cellular high-energy metabolism in-vivo. However, its acquisition suffers from a low sensitivity, which necessitates large voxel sizes or multiple averages to achieve an acceptable signal-to-noise ratio (SNR), resulting in long scan times.
Materials And Methods: To overcome these limitations, we propose an acquisition and reconstruction scheme for FID-MRSI sequences.