The Functional Movement Screen (FMS) is a tool that quantifies movement patterns as a way to detect performance asymmetries. Although previous study has investigated the reliability of FMS, no current research has examined intrarater reliability or how clinical experience plays a role in the reliability of this tool. In this controlled laboratory study design, repeated measures were used to investigate how experience using the FMS and clinical experience as an athletic trainer (AT) affects the intrarater reliability of FMS testing. Before the data collection, 3 individuals recruited from the university community provided signed informed consent to serve as videotaped models performing the FMS test. The participants (raters) in the study, with different levels of FMS and clinical experience, viewed each of the 3 videotaped models and rated the video models on each exercise of the FMS according to the script that was presented by one of the study investigators. A week later, the participants watched the same videos again, in a different randomized order, and rated each video model on each exercise. After the scores from the participants were collected from both sessions, the intersession scores of the FMS were examined to establish intrarater reliability of all the participants. Additionally, the intrarater reliability of different groups of clinicians and students was compared to make inferences about the influence of clinical experience as an AT along with previous experience using the FMS. The ATs with at least 6 months of experience using the FMS (ATExp group) had the strongest intrarater reliability [intraclass correlation coefficients, ICC (2,1): 0.946], followed by the AT group with moderate reliability [ICC (2,1): 0.771]. This study indicates that intrarater reliability is strong and seems to strengthen when the individuals have experience using the FMS in addition to clinical experience.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0b013e31825c32a8DOI Listing

Publication Analysis

Top Keywords

intrarater reliability
28
clinical experience
20
experience fms
16
fms
11
reliability
9
experience
9
functional movement
8
movement screen
8
reliability fms
8
fms clinical
8

Similar Publications

Purpose: Arthrogenic muscle inhibition (AMI) is a reflexive shutdown of the quadriceps muscles following a knee injury or surgery that presents with or without hamstring contracture. This complication can be classified according to the SANTI classification, but the reproducibility of this clinical classification has not yet been demonstrated.

Methods: This single-centre longitudinal observational study included 140 patients who were within 6 weeks of an ACL rupture.

View Article and Find Full Text PDF

Purpose: No studies have explored the reliability of the Rigo classification system using surface topography (ST), which would allow optimization without radiation exposure. This study aims to measure and compare the intra- and inter-observer reliability (Kappa values) and accuracy of the Rigo system between ST and X-ray for overall types and subtypes.

Methods: X-ray and ST images of 31 adolescent idiopathic scoliosis patients were selected.

View Article and Find Full Text PDF

We present an approach for evaluating abdominal computed tomography (CT) scans that generates reproducible measures relevant to donor site morbidity after abdominally based breast reconstruction. Seventeen preoperative CT metrics were measured in 20 patients with software: interanterior superior iliac spine distance; abdominal wall protrusion; interrectus distance; rectus abdominis width, thickness, and width-to-thickness ratio; abdominal wall thickness; subcutaneous fat volume; visceral fat volume; right/left psoas volumes and densities; and right/left rectus abdominis volumes and densities. Two operators performed measures to determine interrater reliability (n = 10).

View Article and Find Full Text PDF

Objective: To evaluate the intrarater and interrater reliability of the Clinical Frailty Scale-Spain (CFS-España) and FRAIL-España and the internal consistency of the FRAIL-España when implemented in critically ill patients by intensive care nurses and physicians.

Design: Descriptive, observational and metric study.

Setting: intensive care unit (ICU) of Spain.

View Article and Find Full Text PDF

Background: The sacroiliac joints (SIJ) are specialized articulations in the pelvis that allow load transfer between the upper and lower body. Traumatic pelvic disruption often requires surgical fixation of at least one of these joints. Subsequent SIJ pain is associated with asymmetries in joint laxity or stiffness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!