Intention-based EMG control for powered exoskeletons.

IEEE Trans Biomed Eng

BioRobotics Institute, Scuola Superiore Sant'Anna,Pisa, Italy.

Published: August 2012

Electromyographical (EMG) signals have been frequently used to estimate human muscular torques. In the field of human-assistive robotics, these methods provide valuable information to provide effectively support to the user. However, their usability is strongly limited by the necessity of complex user-dependent and session-dependent calibration procedures, which confine their use to the laboratory environment. Nonetheless, an accurate estimate of muscle torque could be unnecessary to provide effective movement assistance to users. The natural ability of human central nervous system of adapting to external disturbances could compensate for a lower accuracy of the torque provided by the robot and maintain the movement accuracy unaltered, while the effort is reduced. In order to explore this possibility, in this paper we study the reaction of ten healthy subjects to the assistance provided through a proportional EMG control applied by an elbow powered exoskeleton. This system gives only a rough estimate of the user muscular torque but does not require any specific calibration. Experimental results clearly show that subjects adapt almost instantaneously to the assistance provided by the robot and can reduce their effort while keeping full control of the movement under different dynamic conditions (i.e., no alterations of movement accuracy are observed).

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2012.2198821DOI Listing

Publication Analysis

Top Keywords

emg control
8
provided robot
8
movement accuracy
8
assistance provided
8
intention-based emg
4
control powered
4
powered exoskeletons
4
exoskeletons electromyographical
4
electromyographical emg
4
emg signals
4

Similar Publications

A Review: Developments in Hardware Systems of Active Ankle Orthoses.

Sensors (Basel)

December 2024

Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-nishi, Miyazaki 889-2192, Japan.

Active ankle orthoses which have been designed over the past few years by diverse sources were critically reviewed in this paper. It begins by providing an overview of the anatomy of the ankle joint complex, establishing a basis for understanding the subsequent discussion on the research challenges and design difficulties associated with developing active ankle orthosis devices. The review systematically examined the mechanisms, actuation methods, and control strategies utilized in these orthosis devices.

View Article and Find Full Text PDF

Lumbopelvic pain (LBP) is a prevalent condition during pregnancy, affecting a significant proportion of pregnant women. It arises from hormonal, biomechanical, and postural changes, often exacerbating discomfort and impairing quality of life. This study aimed to evaluate the effects of targeted motor control interventions focusing on sternal alignment on spinal alignment, pain, and muscle activity in pregnant women at risk of preterm birth.

View Article and Find Full Text PDF

Thigh muscles greatly influence knee joint loading, and abnormal loading significantly contributes to the progression of knee osteoarthritis (KOA). Muscle weakness in KOA patients is common, but the specific contribution of each thigh muscle to joint loading is unclear. The gait data from 10 severe female KOA patients and 10 controls were collected, and the maximum isometric forces of the biceps femoris long head (BFL), semitendinosus (ST), rectus femoris (RF), vastus lateralis (VL), and vastus medialis (VM) were calibrated via ultrasound.

View Article and Find Full Text PDF

Development of a Wearable Electromyographic Sensor with Aerosol Jet Printing Technology.

Bioengineering (Basel)

December 2024

Movement Control and Neuroplasticity Research Group, KU Leuven, Tervuursevest 101, 3001 Leuven, Belgium.

Electromyographic (EMG) sensors are essential tools for analyzing muscle activity, but traditional designs often face challenges such as motion artifacts, signal variability, and limited wearability. This study introduces a novel EMG sensor fabricated using Aerosol Jet Printing (AJP) technology that addresses these limitations with a focus on precision, flexibility, and stability. The innovative sensor design minimizes air interposition at the skin-electrode interface, thereby reducing variability and improving signal quality.

View Article and Find Full Text PDF

Multi-Exoskeleton Performance Evaluation: Integrated Muscle Energy Indices to Determine the Quality and Quantity of Assistance.

Bioengineering (Basel)

December 2024

Department of Advanced Robotics (ADVR), Istituto Italiano di Tecnologia (IIT), 16163 Genova, Italy.

The assessment of realistic work tasks is a critical aspect of introducing exoskeletons to work environments. However, as the experimental task's complexity increases, the analysis of muscle activity becomes increasingly challenging. Thus, it is essential to use metrics that adequately represent the physical human-exoskeleton interaction (pHEI).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!