Background: Baumann angle (BA) is a common measure of coronal plane alignment of the distal humerus. We hypothesize that the reliability of measuring BA would be improved by using the medial and lateral cortical margins of the humerus seen on plain x-ray, rather than the estimated central humeral line, which is the "standard" technique. Further, we analyze whether the amount of humerus visible on the film improves the reliability of the method.
Methods: A total of 71 anteroposterior elbow digital radiographs from patients aged 0 to 12 were measured 3 times by 5 qualified observers. Each digital measurement included (1) BA using the estimated central humeral line; (2) BA using the medial humeral line (BA-MHL); and (3) BA using the lateral humeral line (BA-LHL). Inadequate radiographs or those showing any indication of current or previous fracture were excluded. Intraobserver reliability was estimated for each rater using a 1-way analysis of variance model and interobserver reliability of each set of measurements was estimated using a 2-way analysis of variance.
Results: The mean and SD for the BA, BA-MHL, and BA-LHL in females were 70.0 (6.73), 68.0 (6.84), and 72.3 (7.93), respectively, and for males 73.0 (5.22), 70.0 (5.56), and 76.0 (6.18), respectively. Intraobserver reliability (intraclass correlation coefficient) for BA, BA-MHL, and BA-LHL averaged 0.85, 0.92, and 0.90, respectively. Average interobserver reliability (intraclass correlation coefficient) for BA, BA-MHL, and BA-LHL were 0.79, 0.71, and 0.76, respectively. Intraobserver and interobserver reliability of BA and BA-LHL were significantly improved when at least 7 cm of humerus was visible on the x-ray, as compared with <7 cm visible.
Conclusions: Intrarater reliability is better for both BA-LHL and BA-MHL than for standard BA (using the estimated central humeral axis). Interrater reliability was best using standard BA. Reliability of all methods is improved when >7 cm of the distal humerus is visible on the radiograph. In addition, at least 7 cm of the distal humerus on anteroposterior radiographs improves reliability of measuring BA.
Level Of Evidence: Diagnostic study-Level II.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BPO.0b013e318251969f | DOI Listing |
Eur J Orthop Surg Traumatol
December 2024
University Hospitals Cleveland Medical Center, Cleveland, USA.
Purpose: Olecranon osteotomy has been associated with loss of reduction, nonunion, implant failure, and migration of wires. We aim to evaluate quality of reduction of the osteotomy site as a predictor of olecranon osteotomy nonunion.
Methods: One hundred and twenty-five distal humerus fractures that underwent open reduction internal fixation (ORIF) were reviewed.
Injury
December 2024
Department of Orthopaedics, Larnaca General Hospital, State Health Services Organisation, Larnaca, Cyprus.
The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.
View Article and Find Full Text PDFJ Vet Med Sci
December 2024
The University Museum, The University of Tokyo.
The significance of forelimb morphology has been discussed with a focus on specific morphological aspects; nonetheless, the correlation of overall morphology, including various linear measurements, with respect to ecological preference and adaptation has not been extensively explored, particularly using multiple taxa. We investigated the morphological characteristics of the long bones in the forelimbs of mammalian species and their relationship with specific functional adaptations using 20 linear measurements and 22 terrestrial species from 7 orders. Principal component analysis and canonical discriminant analysis showed that the lengths of the humerus, radius, and ulna as well as the distance from the smallest width to the proximal and distal ends, and the deltoid tuberosity length distinguished four adaptations: arboreal, terrestrial, fossorial, and semi-aquatic.
View Article and Find Full Text PDFThe standard treatment for displaced pediatric supracondylar fracture of humer us (PSCFH) is closed reduction and percutaneous pinning under image intensifier guidance. This technical note describes Kapandji intrafocal pinning technique (KIPT) for achieving optimal fracture reduction and stable fixation in Gartland Type III or IV extension type PSCFH. In KIPT, a K wire was introduced into the fracture site from the posterior aspect, fracture manipulation was done by levering with wire reducing the posterior displacement of the distal fragment and the wire was fixed to the anterior cortex of the proximal fragment.
View Article and Find Full Text PDFEinstein (Sao Paulo)
December 2024
Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
Epiphyseal displacement of the distal humerus is rare and difficult to diagnose. In addition, the literature on the prognosis and treatment is limited. Here, we present a case of distal humeral physeal separation with significant displacement in a neonate.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!