EEG monitoring of therapy for neonatal seizures.

Dev Med Child Neurol

Department of Paediatrics, University Hospital of Wales, Heath Park, Cardiff.

Published: October 1990

Eleven neonates with seizures had continuous EEGs recorded before and up to several hours after administration of anticonvulsant therapy. Six of seven babies given phenobarbitone responded clinically, but in four of these the EEG showed that seizure discharges either persisted or recurred within two hours. Chloral hydrate had no immediate effect in one case and only a doubtful influence on EEG seizure activity in another. Three babies were given benzodiazepines: after an apparently rapidly effective bolus dose of diazepam, recurrence of seizure discharges was almost immediate. Infusions of diazepam or clonazepam eventually were associated with persistent control of clinical and EEG seizures. In the treatment of neonatal seizures, conventional anticonvulsants are rarely completely effective: EEG monitoring is essential for optimal therapeutic intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1469-8749.1990.tb08097.xDOI Listing

Publication Analysis

Top Keywords

eeg monitoring
8
neonatal seizures
8
eeg seizure
8
seizure discharges
8
eeg
5
monitoring therapy
4
therapy neonatal
4
seizures
4
seizures eleven
4
eleven neonates
4

Similar Publications

BACKGROUND: Status epilepticus is an emergency, and applying electroencephalography (EEG) monitoring is an important part of diagnosing and treating seizure. The use of rapidly applied limited array continuous EEG (rapid EEG) has become technologically feasible in recent years. Nurse-led protocols using rapid EEG as a point-of-care monitor are increasingly being adopted.

View Article and Find Full Text PDF

Developmental and epileptic encephalopathies constitute a group of severe epilepsies, with seizure onset typically occurring in infancy or childhood, and diverse clinical manifestations, including neurodevelopmental deficits and multimorbidities. Many have genetic aetiologies, identified in up to 50% of individuals. Whilst classically considered paediatric disorders, most are compatible with survival into adulthood, but their adult phenotypes remain inadequately understood.

View Article and Find Full Text PDF

Aggression is commonly associated with increased experiences of peer rejection and maladaptive social information processing biases throughout development. Little is known about the neural correlates of peer rejection that might underlie social information processing biases, and whether these neural correlates are common or different across early- and mid-adolescents on a continuum of aggression. Using the Cyberball task, we examined mediofrontal theta (4-7 Hz) event-related EEG spectral power during conditions of explicit and ambiguous social exclusion in 117 participants (57 early adolescents, ages 10-12 years, and 60 mid-adolescents, ages 14-16 years).

View Article and Find Full Text PDF

Traumatic brain injury (TBI) is a global public health condition that causes cognitive and behavioral deficits. This protocol assesses the potential of quantitative electroencephalogram (EEG) biomarkers, associated with inflammatory indicators, to predict mortality and functional recovery in patients with severe TBI. Through continuous monitoring and analysis of abnormal brain activity patterns, the protocol aims to personalize therapeutic interventions and improve patient quality of life.

View Article and Find Full Text PDF

Brain-Computer Interface and Electrochemical Sensor Based on Boron-Nitrogen Co-Doped Graphene-Diamond Microelectrode for EEG and Dopamine Detection.

ACS Sens

January 2025

Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384, PR China.

The simultaneous detection of electroencephalography (EEG) signals and neurotransmitter levels plays an important role as biomarkers for the assessment and monitoring of emotions and cognition. This paper describes the development of boron and nitrogen codoped graphene-diamond (BNGrD) microelectrodes with a diameter of only 200 μm for sensing EEG signals and dopamine (DA) levels, which have been developed for the first time. The optimized BNGrD microelectrode responded sensitively to both EEG and DA signals, with a signal-to-noise ratio of 9 dB for spontaneous EEG signals and a limit of detection as low as 124 nM for DA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!