A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Medical image diagnostics based on computer-aided flow analysis using magnetic resonance images. | LitMetric

Medical image diagnostics based on computer-aided flow analysis using magnetic resonance images.

Comput Med Imaging Graph

School of Aerospace, Mechanical & Manufacturing Engineering and Health Innovations Research Institute (HIRi), RMIT University, Bundoora, Victoria, Australia.

Published: October 2012

Most of the cardiac abnormalities have an implication on hemodynamics and affect cardiovascular health. Diagnostic imaging modalities such as computed tomography and magnetic resonance imaging provide excellent anatomical information on myocardial structures, but fail to show the cardiac flow and detect heart defects in vivo condition. The computerized technique for fluid motion estimation by pixel intensity tracking based on magnetic resonance signals represents a promising technique for functional assessment of cardiovascular disease, as it can provide functional information of the heart in addition to analysis of its anatomy. Cardiovascular flow characteristics can be measured in both normal controls and patients with cardiac abnormalities such as atrial septal defect, thus, enabling identification of the underlying causes of these flow phenomena. This review paper focuses on an overview of a flow analysis scheme based on computer-aided evaluation of magnetic resonance intensity images, in comparison with other commonly used medical imaging modalities. Details of the proposed technique are provided with validations being conducted at selected abnormal cardiovascular patients. It is expected that this new technique can potentially extend applications for characterizing cardiovascular defects and their hemodynamic behavior.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compmedimag.2012.04.003DOI Listing

Publication Analysis

Top Keywords

magnetic resonance
16
based computer-aided
8
flow analysis
8
cardiac abnormalities
8
imaging modalities
8
flow
5
cardiovascular
5
medical image
4
image diagnostics
4
diagnostics based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!