A 1-piece, tripod-shaped, acrylic intraocular lens was implanted in the posterior chamber after phacoemulsification to remove cataracts in 20 eyes of 16 dogs. Biomicroscopy and intraocular pressure measurements were performed at 1, 8, 30, and 90 days after surgery; retinoscopy was performed at day 30. Complications were not encountered during implantation of the lens. All dogs had mild ocular inflammation characterized predominantly by aqueous flare and mild corneal edema at day 1, which resolved completely by day 8; 3 eyes had mild hyphema at day 1, which resolved by day 8. Three eyes developed fibrin in the anterior chamber, which resolved by day 30. Two eyes developed distorted pupils caused by adherence of vitreous humor or fibrin to the incision site. Postoperative intraocular pressure ranged from 7 to 21 mm Hg. Implantation resulted in 9 emmotropic eyes, 5 myopic eyes, and 6 hyperopic eyes. Maintenance of central lens position was excellent in 19 eyes; in 1 eyes, a disclocated superior haptic at day 2 was easily repositioned.