Functional calibration techniques have been proposed as an alternative to regression equations for estimating the position of the hip within the pelvic co-ordinate system for clinical gait analysis. So far validation of such techniques has focussed on healthy adults. This study evaluated a range of techniques based on regression equations or functional calibration procedures techniques in 46 children representative of those attending a major clinical gait analysis service against previously validated 3-D ultrasound techniques for determining the hip joint centre. Best agreement with ultrasound for the position of the hip within the pelvic coordinate system was found for the Harrington equations (mean 14 mm, sd 8 mm). Sphere fitting (mean≈22 mm, sd 11 mm) performed better than transformational techniques applied locally (mean≈33 mm, sd 12 mm) or globally (mean=30 mm, sd 14 mm). The participants with cerebral palsy showed reduced range of movement compared with healthy adults. Differences between these results and studies modelling the effects of simulated noise on functional techniques can probably be attributed to differences between that noise and the soft tissue displacements that are actually occurring.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2012.03.011DOI Listing

Publication Analysis

Top Keywords

clinical gait
12
gait analysis
12
hip joint
8
joint centre
8
techniques
8
cerebral palsy
8
functional calibration
8
regression equations
8
position hip
8
hip pelvic
8

Similar Publications

Objective: We aimed to investigate the association of sociodemographic, clinical and functional characteristics with the volume of transitions and specific trajectories across living and care settings.

Methods: Using data from the Swedish National Study on Aging and Care in Kungsholmen study, we identified transitions across home (with or without social care), nursing homes, hospitals and postacute care facilities among 3021 adults aged 60+. Poisson and multistate models were used to investigate the association between sociodemographic, clinical and functional characteristics and both the overall volume and hazard ratios (HRs) of specific transitions.

View Article and Find Full Text PDF

OpenCap, a smartphone-based markerless system, offers a cost-effective alternative to traditional marker-based systems for gait analysis. However, its kinematic measurement accuracy must be evaluated before widespread use in clinical practice. This study aimed to evaluate OpenCap for lower-limb joint angle measurements during walking in patients with knee osteoarthritis (OA) and to compare error metrics between patients and healthy controls.

View Article and Find Full Text PDF

The Pediatric Hip Physical Exam.

Curr Rev Musculoskelet Med

January 2025

UCSF Department of Orthopaedic Surgery, 500 Parnassus Ave, MU 320W, San Fransciso, CA, 94143, USA.

Purpose Of Review: Atraumatic hip pain in children is one of the most common orthopaedic complaints in this population. This review details the important elements of the pediatric hip physical exam and provides an overview of pertinent clinical exam findings in specific diagnoses of common pediatric hip pathology.

Recent Findings: A thorough physical exam is critical for the diagnosis of pediatric hip pathology, as many conditions have exam findings that are very commonly associated with the pathology, if not pathognomonic for the disorder.

View Article and Find Full Text PDF

Sarcopenia, an age-related decline in skeletal muscle mass, strength, and function, is increasingly recognized as a significant condition in the aging population, particularly among those with cardiovascular diseases (CVD). This review provides a comprehensive synthesis of the interplay between sarcopenia and cardiogeriatrics, emphasizing shared mechanisms such as chronic low-grade inflammation (inflammaging), hormonal dysregulation, oxidative stress, and physical inactivity. Despite advancements in diagnostic frameworks, such as the EWGSOP2 and AWGS definitions, variability in criteria and assessment methods continues to challenge standardization.

View Article and Find Full Text PDF

Introduction: Gait analysis is a vital tool in the assessment of human movement and has been widely used in clinical settings to identify potential abnormalities in individuals. However, there is a lack of consensus on the normative values for gait metrics in large populations. The primary objective of this study is to establish a normative database of spatiotemporal gait metrics across various age groups, contributing to a broader understanding of human gait dynamics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!