In this paper, we describe a method for the preparation of easy-to-use reversed-phase monolithic microbore columns. Polyetheretherketone (PEEK) tubing with an outer diameter of 1/16″ and an inner diameter of 1.0 mm was used as a column housing (empty column), and in it lauryl methacrylate (LMA) was copolymerized with ethylene dimethacrylate (EDMA). In order to chemically anchor the polymer monolith to the tube wall, the inner wall surface was pretreated by the following two-step procedure. (1) 50% sulfuric acid was filled into the PEEK tubing and left to stand for 6 h to generate sulfonate groups on the surface. (2) After washing with Milli-Q water, the sulfonated PEEK surface was brought into contact with 1 M glycidyl methacrylate in dichloromethane (or acetone) at 40°C for 4 h to introduce methacryloyl groups via the reaction of sulfonate groups and epoxy groups. Mechanical strength and column efficiency of the resulting monoliths were evaluated through the separation of a series of alkylbenzenes in acetonitrile-water (50:50, v/v) eluent over the flow rate range of 50-750 μL/min (corresponding to 1.7-25.5 mm/s). The poly(LMA-co-EDMA) monolith provided acceptable column efficiency of 2000 theoretical plates/10 cm (HETP value of 50 μm) for amylbenzene (separation factor k=40) and low flow resistance of 0.5 MPa/10 cm at a normal flow rate of 50 μL/min. The methacryloylated PEEK tubing tightly held the monolith, and the monolithic column exhibited good pressure resistance up to 15 MPa, allowing rapid separation at a 15-20 fold higher flow rate than normal.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2012.04.030DOI Listing

Publication Analysis

Top Keywords

peek tubing
12
flow rate
12
sulfonate groups
8
column efficiency
8
column
5
chemical anchoring
4
anchoring lauryl
4
lauryl methacrylate-based
4
methacrylate-based reversed
4
reversed phase
4

Similar Publications

What is the weakest point of a secured aortic cannula in central extracorporeal membrane oxygenation?

Perfusion

May 2024

Congenital Heart Center, Division of Cardiovascular Surgery, Departments of Surgery and Pediatrics, University of Florida, Gainesville, Florida, USA.

Article Synopsis
  • * Results showed that in tissue models, the sutures pulled through the aortic tissue under low force, while the stand model demonstrated that two purse-string sutures with ligaclips effectively held the cannula against much higher forces.
  • * The conclusion emphasized the importance of securing ECMO cannulas to prevent dislodgement and suggested that larger diameter sutures are better at withstanding force, with two medium hemostatic clips providing reliable fixation.
View Article and Find Full Text PDF

Multicomponent reactions offer efficient and environmentally friendly strategies for preparing monoliths suitable for applications in analytical chemistry. In the described study, a multicomponent reaction was utilized for the one-pot miniaturized preparation of a poly(propargyl amine) polymer inside commercial silica-lined PEEK tubing. The reaction involved only small amounts of reagents and was characterized by atom economy.

View Article and Find Full Text PDF

On-column capillary suppressor for open tubular ion chromatography.

Anal Chim Acta

April 2024

Hubei Key Laboratory of Yangtze Catchment Environmental Aquatic Science, School of Environmental Studies, China University of Geosciences, Wuhan, 430078, Hubei, China.

Background: Suppressors with different dead volumes are required to match different suppressed ion chromatography systems. Especially for suppressed open tubular ion chromatography (SOTIC), the dead volume is a critical parameter. Both connection tubes between open tubular (OT) columns and suppressors and the dead volumes of the suppressors should be as short/small as possible to minimize peak dispersion.

View Article and Find Full Text PDF

The recovery and recycling of metals that generate toxic ions in the environment is of particular importance, especially when these are tungsten and, in particular, thorium. The radioactive element thorium has unexpectedly accessible domestic applications (filaments of light bulbs and electronic tubes, welding electrodes, and working alloys containing aluminum and magnesium), which lead to its appearance in electrical and electronic waste from municipal waste management platforms. The current paper proposes the simultaneous recovery of waste containing tungsten and thorium from welding electrodes.

View Article and Find Full Text PDF

Shear bond strength characteristics on surface treatment modalities of CAD-CAM resin polymers.

J Prosthodont

January 2025

Department of Restorative Dentistry, Graduate Prosthodontics OHSU, Portland, Oregon, USA.

Purpose: The purpose of this in vitro study was to analyze the shear bond strength of composite resin to a commercially available high-performance polymer material for fixed, screw-retained full arch restorations.

Material And Methods: A total of 135 computer-aided design and computer-aided manufacturing, high-performance polymer (HPP) blocks were cut and obtained from discs (Trilor 95, Harvest Dental, Brea, CA). The samples were 10 mm × 10 mm × 10 mm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!