Purpose: To evaluate the root fracture strength of human single-rooted premolars restored with customized fiberglass post-core systems after fatigue simulation.

Methods: 40 human premolars had their crowns cut and the root length was standardized to 13 mm. The teeth were endodontically treated and embedded in acrylic resin. The specimens were distributed into four groups (n=10) according to the restorative material used: prefabricated fiber post (PFP), PFP+accessory fiber posts (PFPa), PFP+unidirectional fiberglass (PFPf), and unidirectional fiberglass customized post (CP). All posts were luted using resin cement and the cores were built up with a resin composite. The samples were stored for 24 hours at 37 degrees C and 100% relative humidity and then submitted to mechanical cycling. The specimens were then compressive-loaded in a universal testing machine at a crosshead speed of 0.5 mm/minute until fracture. The failure patterns were analyzed and classified. Data was submitted to one-way ANOVA and Tukey's test (alpha = 0.05).

Results: The mean values of maximum load (N) were: PFP - 811.4 +/- 124.3; PFPa - 729.2 +/- 157.2; PFPf- 747.5 +/- 204.7; CP - 762.4 +/- 110. Statistical differences were not observed among the groups. All groups showed favorable restorable failures. Fiberglass customized post did not show improved fracture resistance or differences in failure patterns when compared to prefabricated glass fiber posts.

Download full-text PDF

Source

Publication Analysis

Top Keywords

fracture resistance
8
fiber posts
8
fiberglass customized
8
customized post
8
failure patterns
8
customized
4
customized fiber
4
fiber glass
4
posts
4
glass posts
4

Similar Publications

Background: Conservative dentistry introduced modern restoration designs, contributing to the greater use of partial-coverage ceramic restorations. New strong bondable ceramic materials made fabricating partial coverage ceramic restorations easier to restore the badly destructed teeth.

Aim Of The Study: This study investigated the impact of three distinct overlay preparation designs on the marginal fit (both before and after thermal aging) and the fracture resistance of overlay restorations fabricated using advanced zirconia-reinforced lithium disilicate (ALD) CAD/CAM glass-ceramic blocks.

View Article and Find Full Text PDF

Hierarchically aligned heterogeneous core-sheath hydrogels.

Nat Commun

January 2025

Institute of Innovative Materials, Department of Chemistry, College of Science, Southern University of Science and Technology, Shenzhen, China.

Natural materials with highly oriented heterogeneous structures are often lightweight but strong, stiff but tough and durable. Such an integration of diverse incompatible mechanical properties is highly desired for man-made materials, especially weak hydrogels which are lack of high-precision structural design. Herein, we demonstrate the fabrication of hierarchically aligned heterogeneous hydrogels consisting of a compactly crosslinked sheath and an aligned porous core with alignments of nanofibrils at multi-scales by a sequential self-assembly assisted salting out method.

View Article and Find Full Text PDF

Comparative finite element analysis: internal fixation plate versus intramedullary nail for neer type III-VI proximal humeral fractur.

J Orthop Surg Res

January 2025

Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing, 100020, China.

Background: Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.

Methods: Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.

View Article and Find Full Text PDF

Post-traumatic osteoarthritis (PTOA) is a painful joint disease characterized by the degradation of bone, cartilage, and other connective tissues in the joint. PTOA is initiated by trauma to joint-stabilizing tissues, such as the anterior cruciate ligament, medial meniscus, or by intra-articular fractures. In humans, ~50% of joint injuries progress to PTOA, while the rest spontaneously resolve.

View Article and Find Full Text PDF

The study aimed to evaluate the potential protection against fractures of oral Q10 supplementation in the tibias of rats exposed to nicotine. Nicotine is known to negatively impact bone density and increase the risk of fractures, in addition to affecting other systems such as the gastrointestinal system, impairing its absorption capacity, negatively affecting bone health. To investigate this, eighty male rats were divided into four groups (n = 20) receiving either nicotine hemisulfate or saline solution (SS) for 28 days.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!