Background: It is widely believed that the main function of denticulate ligaments (DLs) is to stabilize the spinal cord within the vertebral canal. The aim of this study was to assess the anatomical and histological structure of the DLs and to document any regional differences.
Methods: Five formalin-fixed adult cadavers were used. The DLs were exposed via the posterior approach, and detailed anatomy and histology of these structures were documented.
Results: The main findings were: (1) each DL is composed of a single narrow fibrous strip that extends from the craniovertebral junction to T12, and each also features 18-20 triangular extensions that attach to the dura at their apices; (2) the triangular extensions are smaller and more numerous at the cervical levels, and are larger and less numerous at the thoracic levels; (3) the apices of the extensions attach to the dura via fibrous bands at cervical levels (each band 3-5 mm long) and lower thoracic levels (21-26 mm long), whereas they attach directly to the dura at upper thoracic levels; (4) the narrow fibrous strip of the DL features longitudinally oriented collagen fibers, whereas the triangular extensions are composed of transverse and obliquely oriented collagen fibers. The collagen fibers are thicker and more abundant at the cervical than at the thoracic levels.
Conclusion: DL histology and anatomy are strongly correlated with the function of this structure at different spinal levels. It is important to have accurate knowledge about DLs as these structures are relevant for clinical procedures that involve the spinal cord or craniovertebral junction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00701-012-1361-x | DOI Listing |
Sci Rep
December 2024
Department of Mathematics, Ghazni University, Ghazni, Afghanistan.
The current manuscript presents a mathematical model of dengue fever transmission with an asymptomatic compartment to capture infection dynamics in the presence of uncertainty. The model is fuzzified using triangular fuzzy numbers (TFNs) approach. The obtained fuzzy-fractional dengue model is then solved and analyzed through fuzzy extension of modified residual power series algorithm, which utilizes residual power series along with Laplace transform.
View Article and Find Full Text PDFOrthop Surg
December 2024
Department of Orthopaedics, Yunfu People's Hospital, Yunfu, China.
Objective: The clivus is trapezoidal in shape with uneven bone structure, the optimal number and position of screws for clival fixation are not clear. Therefore, this study aims to explore the optimization clival screw fixation method for occipitocervical instability using finite element analysis.
Methods: Seven finite element models were developed to evaluate biomechanical properties of clival screw fixation for treating occipitocervical stability, including (i) one clival screw fixation A1 and A2 models; (ii) two clival screws fixation B1 and B2 models; (iii) three clival screws fixation C1 and C2 models; (iv) four clival screws fixation D1 model.
Ann Chir Plast Esthet
December 2024
Department of Plastic, Reconstructive and Aesthetic Surgery, AP-HM, Conception University Hospital, 147, boulevard Baille, 13005 Marseille, France.
Patients who underwent cleft lip surgery in childhood may develop nasal malformation later in life. Various procedures have been described to correct these malformations. This study aims to describe our surgical approach and assess the morphometric outcomes of secondary cleft-lip rhinoplasty performed at the plastic surgery department in Marseille between 2002 and 2022.
View Article and Find Full Text PDFMed Devices (Auckl)
October 2024
Medical Device Development, San Francisco, CA, USA.
Purpose: To concurrently assess and compare the fixation efficacy, invasiveness, and fusion potential of a posterior integrated transfixation cage system to the posterolateral threaded implant and lateral triangular rod systems, in a cadaveric model.
Methods And Materials: Twelve (12) cadaveric sacroiliac joint specimens were utilized and tested within the single-leg stance multidirectional pure moment bending model. Each specimen was tested in the intact, destabilized, treated (using posterior, posterolateral, and lateral systems), and post-fatigue conditions by applying 0 to ± 7.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!