Background: Cryoballoon ablation is a recently introduced technique to isolate the pulmonary veins in patients with atrial fibrillation (AF). It can potentially reduce procedural times and serious complications associated with radiofrequency ablation.

Method: We present data for 200 consecutive patients who underwent cryoballoon ablation for symptomatic AF with a mean follow-up of 16 months.

Results: Over 214 procedures that involved cryoballoon technique the mean procedure and fluoroscopy times fell to 130 and 30 min, respectively. 93.6% of pulmonary veins targeted were isolated with the cryoballoon only and 97.7% could be isolated with the addition of a radiofrequency ablation catheter. At one year 70% of patients in the paroxysmal AF group and 59% of patients in the persistent AF group were free from symptomatic recurrence. Three percent of patients experienced phrenic nerve palsy that persisted beyond the procedure. The major complication rate in this study was 0.9%.

Conclusion: This represents the earliest and largest experience with cryoballoon ablation for AF in Australia. The major complication rate was low with no pulmonary vein stenosis, atrio-oesophageal fistula, stroke or cardiac tamponade in this series. The majority of patients were free from symptomatic recurrence at two years follow up.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hlc.2012.03.123DOI Listing

Publication Analysis

Top Keywords

cryoballoon ablation
12
atrial fibrillation
8
pulmonary vein
8
cryoballoon technique
8
pulmonary veins
8
free symptomatic
8
symptomatic recurrence
8
major complication
8
complication rate
8
cryoballoon
6

Similar Publications

Introduction: A hybrid approach with very high-power short-duration (vHPSD) posteriorly and ablation-index guided HPSD (50 W) anteriorly seems to be an optimal balance between efficiency and effectiveness for point-by-point pulmonary vein isolation (PVI). The aim of the current study is to compare vHPSD/HPSD ablation to cryoballoon ablation (CBA) in patients with symptomatic atrial fibrillation (AF).

Methods And Results: In this retrospective single-center study, we identified 110 consecutive patients who underwent their first PVI with either vHPSD/HPSD (n = 54) or CBA (n = 56).

View Article and Find Full Text PDF

Comparison of Catheter Ablation in Patients with Paroxysmal Non-valvular Atrial Fibrillation and Heart Failure with Preserved Ejection Fraction.

Int J Med Sci

January 2025

Department of Cardiology, The Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, People's Republic of China.

The efficacy of radiofrequency ablation (RFA) in patients with atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) has been established, but the efficacy and safety of cryoballoon ablation (CBA) and pulsed field ablation (PFA) remain unclear. This retrospective cohort study included 223 patients with paroxysmal non-valvular AF and HFpEF who underwent their first AF ablation between January 2017 and December 2021 and were divided into RFA (n = 77), CBA (n = 127), and PFA (n = 19) groups. After a mean follow-up of 11.

View Article and Find Full Text PDF

Comparison of P-wave parameter changes after radiofrequency ablation and cryoballoon ablation for paroxysmal atrial fibrillation: An observational cohort study.

J Electrocardiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK; Department of Cardiovascular Sciences, Clinical Science Wing, University of Leicester, Glenfield Hospital, Leicester, UK; National Institute for Health Research Leicester Research Biomedical Centre, Leicester, UK.

Background: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) can be performed using one-shot cryoballoon ablation (cryo) or point-by-point radiofrequency ablation (RF). This study compares the changes in P-wave parameters between both ablation methods.

Methods: This single-centre retrospective study included contact force RF and second-generation cryo for PAF between 2018 and 2019.

View Article and Find Full Text PDF

Pulsed field ablation (PFA) is a novel nonthermal ablation technique for the treatment of atrial fibrillation (AF) patients, with safety comparable to traditional catheter ablation surgery. The present study aims to evaluate and compare the procedural efficiency and safety profiles of PFA and cryoballoon ablation (CBA) in the management of AF. We performed a systematic search across PubMed, the Cochrane Library, and Embase databases, encompassing the literature up to February 2024, to inform our systematic review and meta-analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!