An experimental approach was performed on 20 giant rabbits to establish the possibilities and limitations of μ-CT for routine processing of nondemineralized bone tissue. Hydroxyapatite (HA) or β-tricalciumphosphate (β-TCP) bead implants or a melange of both, microchambered and solid, were implanted into a standardized and precise defect in the patellar groove. The bone-healing phase was chosen for the histology considering 1 or 2 days, and 2, 3, and 6 weeks. Normal X-ray and μ-CT were applied on all specimens; five specimens in the 6-week stage were additionally processed according to the full range of conventional nondemineralized bone processing methods. μ-CT increased the possibilities of nondemineralized histology with respect to bone morphometry and a complete sequence of sections, thus providing a complete analysis of the bone response. μ-CT was limited in differentiating bone quality, cell analyses, and mineralization stages. The investigation based on normal X-rays is limited to defining integration and excluding the fibrous and bony encapsulation of loose implants. μ-CT allows a 3D evaluation of newly formed bone which is clearly marked against the ceramic implant. It does not allow, however, for the differentiation between woven and lamellar bone, the presentation of the canalicular lacunar system, or on the cell level, revealing canaliculi or details of the mineralization process which can be documented by high-resolution microradiography. Titer dynamics of bone formation remains the domain of polychromatic sequential labeling. The complete sequence of μ-CT slices enhances the possibilities for routine histology, tremendously allowing to the focus on detail histology to topographically well-defined cuts, thus providing more precise conclusions which take into consideration the whole implant.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jemt.21072DOI Listing

Publication Analysis

Top Keywords

nondemineralized bone
12
bone
9
bone tissue
8
complete sequence
8
μ-ct
6
limits μ-ct
4
nondemineralized
4
μ-ct nondemineralized
4
tissue processing
4
processing experimental
4

Similar Publications

This study evaluated the regenerative potential of demineralized dentin-derived matrix (DDM) as a bone graft material in rabbit calvaria. DDM, sourced from extracted teeth, is emerging as an alternative to traditional grafts like allografts and xenografts. We aimed to identify the most effective demineralization protocol to optimize the regenerative capacity of DDM.

View Article and Find Full Text PDF

Introduction: Vitamin D deficiency causes osteoporosis, bone mineralization disorders, and osteomalacia. Osteomalacia is diagnosed using blood biochemical tests, clinical symptoms, and imaging; however, accurate detection of mineralization disorders requires tissue observation. We investigated the prevalence of bone mineralization disorders and their relationship with serum 25-hydroxyvitamin D (25OHD) levels in patients with untreated osteoporosis with femoral neck fractures.

View Article and Find Full Text PDF

The demineralization of bone tissue is used for simulating the osteoporosis related bone loss. This way would be helpful in observations of bone apatite dissolution in microstructural level and may give significant input for understanding crystal-chemistry of bone resorption. In the case of cortical bone, demineralization occurs inhomogeneously, with the formation of a superficial demineralized layer and a transition zone with a gradient of concentration and structural characteristics perpendicular to the reaction advance front.

View Article and Find Full Text PDF

Effects of uphill and downhill walking on post-traumatic osteoarthritis development in mice.

J Physiol

May 2023

Life and Medical Sciences Area, Health Sciences Discipline, Kobe University, Tomogaoka, Suma-ku, Kobe, Japan.

Using destabilization of the medial meniscus (DMM) to induce models of osteoarthritis (OA), we sought to clarify how flat, uphill and downhill walking affects OA-related inflammation and articular cartilage degeneration. Thirty-two male C57BL/6J mice 7 weeks old underwent DMM surgery in their right knee and sham surgery in their left knee, and were then assigned to either the no walking after DMM group or the flat, uphill or downhill walking after DMM group (n = 8/group). After creating the knee OA model, the mice in the walking groups were subjected to treadmill walking 1 day after surgery, which included walking at 12 m/min for 30 min/day, 7 days/week, at inclines of 0, 20, or -20 degrees.

View Article and Find Full Text PDF

Aim: The aim of the present study was to propose the clinical efficacy of the different dentin matrix obtained from three devices (BonMaker, Tooth Transformer, and Smart Dentin Grinder) and to show their morphological, physical, and biochemical characteristics using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) spectroscopy, and Raman spectroscopy.

Research Design And Methods: The study included 70 patients who underwent bone augmentation using the BonMaker, Tooth Transformer, and Smart Dentin Grinder devices. In addition, 84 implants were placed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!