Aim: To prospectively confirm whether a small amount of polyethylene glycol (PEG) ingested after swallowing endoscopy capsule improves image quality and completion rate.

Methods: Forty-four consecutive patients referred to us for capsule endoscopy (CE) were randomized to two groups. All patients were restricted to clear fluids for 12 h before the examination. Patients in group A (22 cases) received no additional preparation, while those in group B (20 cases) ingested 500 mL of PEG within a 2 h period starting 30 min after swallowing the capsule. Clear fluids and meals were allowed 2 h and 4 h after capsule ingestion, respectively. Image quality was assessed as the percentage of visualized bowel surface area as follows: 1: < 25%; 2: 25%-49%; 3: 50%-74%; 4: 75%-89%; 5: > 90%. The small bowel record was divided into five segments by time, and the score for each segment was evaluated. All CE examinations were performed with the Pillcam SB capsule endoscopy system (Given Imaging Co. Ltd., Yoqnem).

Results: This study ended in December 2009, because sample size was considered large enough. A total of 44 patients were enrolled. Two patients in group B were excluded from the analysis because small bowel images could not be obtained from these patients; one had a full stomach, while the other presented with a massive gastric bleed. Thus, 22 patients from group A and 20 patients from group B completed the study. There was no significant difference in age (P = 0.22), sex (P = 0.31), and indication for CE. No significant adverse events occurred in any of the study patients. In group A, image quality deteriorated as the capsule progressed distally. However, in group B, image quality was maintained to the distal small bowel. In each of the five segments, the visibility score was significantly higher in group B than in group A (segment 1: 4.3 ± 0.7 vs 4.7 ± 0.5, P = 0.03; segment 2: 4.2 ± 0.9 vs 4.8 ± 0.4, P = 0.01; segment 3: 4.0 ± 1.0 vs 4.6 ± 0.7, P = 0.04; segment 4: 3.6 ± 1.1 vs 4.5 ± 0.6, P = 0.003; segment 5: 2.7 ± 1.0 vs 4.4 ± 0.8, P = 0.00004). Thus, the use of PEG during CE examination significantly improved image quality in all time segments, and this effect was more pronounced in the distal ileum. The completion rate to the cecum was not significantly different between groups A and B (81.8% vs 85.0%, P = 0.89). There was no difference in the gastric transit time between groups (36.2 ± 35.0 min vs 54.0 ± 56.6 min, P = 0.23), but the small bowel transit time was significantly longer in group A than in group B (246.0 ± 107.0 min vs 171.0 ± 104.0 min, P = 0.04).

Conclusion: The ingestion of a small amount of PEG after the swallowing of an endoscopy capsule significantly improved CE image quality, but did not enhance the completion rate to the cecum.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3332292PMC
http://dx.doi.org/10.3748/wjg.v18.i15.1789DOI Listing

Publication Analysis

Top Keywords

image quality
24
patients group
20
small bowel
16
capsule endoscopy
12
group
11
patients
9
polyethylene glycol
8
capsule
8
small amount
8
swallowing endoscopy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!