This study aimed to assess the interlaboratory reproducibility at four university hospital laboratories in the southeast region of France of the Etest technique for the determination of caspofungin (CAS) and amphotericin B (AMB) MICs and to compare it to the CLSI broth microdilution reference method. Consecutive clinical yeast isolates (n = 198) were included in the study. AMB and CAS MICs were read at 24 and 48 h. Interlaboratory reproducibility was estimated by using (i) an intraclass correlation coefficient (ICC), (ii) essential agreement (EA), and (iii) categorical agreement (CA). For Etest interlaboratory reproducibility for CAS, ICCs were 0.80 (95% confidence interval [CI], 0.76 to 0.84) and 0.81 (95% CI, 0.77 to 0.85) at 24 and 48 h, respectively. For AMB, the ICCs were 0.51 (95% CI, 0.43 to 0.58) and 0.69 (95% CI, 0.63 to 0.74) at 24 and 48 h, respectively. At 48 h, the between-center EAs ranged from 94.4 to 99.0% for both antifungals. For the comparison of the CLSI method and the Etest, the between-technique ICCs were 0.69 (95% CI, 0.63 to 0.74) and 0.62 (95% CI, 0.55 to 0.68) for CAS and AMB, respectively. The EAs ranged from 76.5 to 98.5% for CAS and from 90.3 to 97.4% for AMB according to the centers. CAs ranged from 87.9% to 91.4%, with four very major errors for 2 strains (1 Candida albicans strain and 1 Candida krusei strain), for CAS and from 97.5 to 99.5%, with four major errors, for AMB. In conclusion, the Etest showed a good interlaboratory reproducibility and a good correlation with the CLSI technique. It is well suited for the routine clinical laboratory and can thus be used to monitor clinical yeast isolates' in vitro susceptibilities in this setting.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3405630 | PMC |
http://dx.doi.org/10.1128/JCM.00490-12 | DOI Listing |
J Occup Environ Hyg
January 2025
Metrology Research Centre, National Research Council Canada, Ottawa, Ontario, Canada.
Particle filtration efficiency (PFE) is a critical property of face masks, with the most common test methods using sodium chloride as a challenge aerosol. In the absence of bottom-up uncertainty budgets for PFE, interlaboratory comparisons provide an alternative route to robustly quantify the precision and bias of the method. This work presents the results of several interlaboratory comparisons of particle filtration efficiency performed across a network of laboratories.
View Article and Find Full Text PDFClin Biochem
January 2025
Pathology and Laboratory Medicine Program, Health Sciences Centre, St. John's, Newfoundland and Labrador, Canada; Memorial University of Newfoundland, Health Sciences Centre, St. John's, Newfoundland and Labrador, Canada. Electronic address:
Purpose: Rapid determination of cerebrospinal fluid (CSF) glucose and lactate is required by emergency rooms and intensive care units. Long turnaround time (TAT) on test results negatively impacts timely diagnosis and treatment of neurological infections like meningitis.
Methods: The CSF glucose and lactate assays were evaluated on a blood gas analyzer, Radiometer ABL90 Flex Plus.
Electrophoresis
January 2025
Forensic Sciences Laboratory, Section of Legal Medicine, Department of Medicine and Surgery, Santa Maria Hospital, University of Perugia, Terni, Italy.
The increasing interest in DNA methylation (DNAm) analysis within the forensic scientific community prompted a collaborative project by Ge.F.I.
View Article and Find Full Text PDFJ Proteome Res
January 2025
Centre for Genomic Regulation, The Barcelona Institute of Science and Technology (BIST), Dr. Aiguader 88, Barcelona 08003, Spain.
Quality control procedures play a pivotal role in ensuring the reliability and consistency of data generated in mass spectrometry-based proteomics laboratories. However, the lack of standardized quality control practices across laboratories poses challenges for data comparability and reproducibility. In response, we conducted a harmonization study within proteomics laboratories of the Core for Life alliance with the aim of establishing a common quality control framework, which facilitates comprehensive quality assessment and identification of potential sources of performance drift.
View Article and Find Full Text PDFHum Gene Ther
December 2024
Prevail Therapeutics, New York, New York, USA.
Recombinant adeno-associated virus (AAV) is one of the main viral vector-based gene therapy platforms. AAV is a virus consisting of a ≈25 nm diameter capsid with a ≈4.7 kb cargo capacity.