Biocompatibility analysis of bioglass® 45S5 and biosilicate® implants in the rabbit eviscerated socket.

Orbit

Department of Ophthalmology, Otolaryngology and Head and Neck Surgery, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista (UNESP), São Paulo, SP, Brazil.

Published: June 2012

Purpose: Bioactive glass and bioactive glass-ceramic cone implants were placed in the rabbit eviscerated socket to assess their biocompatibility.

Methods: Fifty-one Norfolk albino rabbits underwent evisceration of the right eye followed by implantation of cones made from Bioglass(®) 45S5 (control group) and two types of bioactive glass-ceramic (Biosilicate(®)), a single- and a two-phase bioactive glass-ceramic implants into the scleral cavity. Postoperative reactions, animal behavior and socket conditions were monitored daily. Clinical exam, biochemical evaluations, and orbit computed tomographic scan were done at 7, 90, and 180 days post-procedure. After that, the animals were euthanized, and the orbital content was removed and prepared to light microscopy with morphometric evaluation and scanning electron microscopy examination. Statistical analysis was done by parametric and non-parametric analysis of variance, complemented by Dunn's and Tukey's tests (p < 0.05).

Results: All animals did not develop systemic toxicity throughout the experimental period and also did not have orbit infection, implant migration or extrusion. Morphological analysis demonstrated pseudocapsule around all implants. Bioglass(®) and single-phase Biosilicate(®) implants induced less inflammation and pseudocapsule formation than two-phase Biosilicate(®) cones. Seven days post-procedure, the inflammatory reaction was intense and gradually decreased throughout the experiment. Tissue reaction was least intense in animals receiving Bioglass(®) implants.

Conclusions: We observe discrete differences among the studied materials, with best responses obtained with use of Bioglass(®) 45S5 and single-phase Biosilicate(®). The authors agree these implants might be useful in the management of the anophthalmic socket.

Download full-text PDF

Source
http://dx.doi.org/10.3109/01676830.2011.648798DOI Listing

Publication Analysis

Top Keywords

bioactive glass-ceramic
12
bioglass® 45s5
8
implants rabbit
8
rabbit eviscerated
8
eviscerated socket
8
biocompatibility analysis
4
analysis bioglass®
4
45s5 biosilicate®
4
biosilicate® implants
4
socket purpose
4

Similar Publications

Chronic osteomyelitis of the maxillofacial bones (i.e., jaw bones) is a persistent infection that requires effective treatment.

View Article and Find Full Text PDF

The bioactive glass-ceramic spacer (BGS)-7, a biosynthetic intervertebral fusion material introduced in 2014, has not been the subject of comparative clinical studies on anterior cervical discectomy and fusion (ACDF) surgery. This study, for the first time, aims to compare the radiological and clinical outcomes of the renewed BGS-7, released in 2019, with those of an allograft spacer. The comparison includes a finite element analysis of the biomechanical properties of each implant, adding a novel dimension to the research.

View Article and Find Full Text PDF

Lithium-containing 45S5 Bioglass-derived glass-ceramics have antioxidant activity and induce new bone formation in a rat preclinical model of type 1 diabetes mellitus.

Biomed Mater

November 2024

Laboratorio de Biomateriales, Grupo Interdisciplinario en Materiales-IESIING, Universidad Católica de Salta, grupo vinculado al INTECIN UBA-CONICET, Salta, Argentina.

Article Synopsis
  • * Lithium (Li) has been found to have beneficial osteogenic and antioxidant effects, making it a good candidate for enhancing bone tissue repair in diabetics when released from bioactive glass-ceramic materials.
  • * A study showed that glass-ceramic microparticles created from a specific type of bioactive glass demonstrated antioxidant activity and promoted bone formation in a rat model of type 1 DM, suggesting their potential use in regenerative medicine for bone tissue.
View Article and Find Full Text PDF

Advancements in reliability of mechanical performance of 3D PRINTED Ag-doped bioceramic antibacterial scaffolds for bone tissue engineering.

Biomater Adv

January 2025

Department of Chemical Engineering & Materials Science, Michigan State University, East Lansing, MI, USA; Department of Chemical Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece. Electronic address:

Article Synopsis
  • * A promising alternative is a 3D porous scaffold made with fused filament fabrication (FFF) technology combined with silver-doped bioactive glass-ceramic particles, which shows potential for helping bone regeneration and has antibacterial properties.
  • * The study evaluates the mechanical strength and antibacterial effectiveness of these scaffolds through various tests, demonstrating they are not only strong but also support cell growth, making them a viable solution for bone repair.
View Article and Find Full Text PDF

The failure of bone regeneration has been considered as a serious problem that troubling patients for decades, most of which was resulted by the poor angiogenesis and chronic inflammation after surgery. Among multiple materials applied in the repair of bone defect, silicate bioceramics attracted researchers because of its excellent bioactivity. The purpose of this study was to detect the effect of specific bioactive glass ceramic (AP40, based on crystalline phases of apatite and wollastonite) on angiogenesis and the subsequent bone growth through the modulation of macrophages.

View Article and Find Full Text PDF