Precision of fit of titanium and cast implant frameworks using a new matching formula.

Int J Dent

Division of Prosthodontics, Department of Biologic and Material Science, The University of Michigan, School of Dentistry, 1011 North University Avenue, Ann Arbor, MI 48109-1078, USA.

Published: August 2012

Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single edentulous CAD/CAM surgical guide were separated in two groups and resin patterns simulating the framework for a fixed complete denture developed. Five casts were sent to dental laboratories to invest, cast in a Palladium-Gold alloy and fit the framework. Ten casts had the resin pattern scanned for fabrication of milled bars in Titanium. Using measuring software, positions of implant replicas in the definitive model were recorded. The three dimensional spatial orientation of each implant replica was matched to the implant replica. Results. Results demonstrated the mean vertical gap of the Cast framework was 0.021 (+0.004) mm and 0.012 (0.002) mm determined by fixed and unfixed best-fit matching coordinate system. For Titanium frameworks they were 0.0037 (+0.0028) mm and 0.0024 (+0.0005) mm, respectively. Conclusions. Milled one-piece Titanium fixed complete denture frameworks provided a more accurate precision of fit then traditional cast frameworks.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3328952PMC
http://dx.doi.org/10.1155/2012/374315DOI Listing

Publication Analysis

Top Keywords

precision fit
12
fixed complete
12
complete denture
12
milled one-piece
8
one-piece titanium
8
titanium fixed
8
denture frameworks
8
cast frameworks
8
implant replica
8
frameworks
7

Similar Publications

Regulation of Glutamate Transporter Type 1 by TSA and the Antiepileptic Mechanism of TSA.

Neurochem Res

January 2025

Huazhong University of Science and Technology, Tongji Medical College, Wuhan, Hubei, 430000, China.

Epilepsy (EP) is a neurological disorder characterized by abnormal, sudden neuronal discharges. Seizures increase extracellular glutamate levels, causing excitotoxic damage. Glutamate transporter type 1 (GLT-1) and its human homologue excitatory amino acid transporter-2 (EAAT2) clear 95% of extracellular glutamate.

View Article and Find Full Text PDF

Aims: Drug-refractory epilepsy (DRE) refers to the failure of controlling seizures with adequate trials of two tolerated and appropriately chosen anti-seizure medications (ASMs). For patients with DRE, surgical intervention becomes the most effective and viable treatment, but its success rate is unsatisfactory at only approximately 50%. Predicting surgical outcomes in advance can provide additional guidance to clinicians.

View Article and Find Full Text PDF

Imaging-guided percutaneous core needle biopsy (PCNB) is currently the most common technique for the investigation of potentially malignant bone lesions. It allows precise needle placement and better visual guidance, leading to improved diagnostic accuracy. Needle tract seeding (NTS) is a rare complication of biopsies in general, and its true incidence remains unknown.

View Article and Find Full Text PDF

Importance: People with kidney failure have a high risk of death and poor quality of life. Mortality risk prediction models may help them decide which form of treatment they prefer.

Objective: To systematically review the quality of existing mortality prediction models for people with kidney failure and assess whether they can be applied in clinical practice.

View Article and Find Full Text PDF

Introduction: Up to 20% of older adults in the United States have mild cognitive impairment (MCI), and about one-third of people with MCI are predicted to transition to Alzheimer's disease (AD) within 5 years. Standard cognitive assessments are long and require a trained technician to administer. We developed the first computerized adaptive test (CAT) based on multidimensional item response theory (MIRT) to more precisely, rapidly, and repeatedly assesses cognitive abilities across the adult lifespan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!