Objectives: To explore peri-implant health (and relation with periodontal status) 4-5 years after implant insertion.
Study Design: A practice-based dental research network multicentre study was performed in 11 Spanish centres. The first patient/month with implant insertion in 2004 was considered. Per patient four teeth (one per quadrant) showing the highest bone loss in the 2004 panoramic X-ray were selected for periodontal status assessment. Bone losses in implants were calculated as the differences between 2004 and 2009 bone levels in radiographs.
Results: A total of 117 patients were included. Of the 408 teeth considered, 73 (17.9%) were lost in 2009 (losing risk: >50% for bone losses ≥7 mm). A total of 295 implants were reviewed. Eight of 117 (6.8%) patients had lost implants (13 of 295 implants installed; 4.4%). Implant loss rate (quadrant status) was 1.4% (edentulous), 3.6% (preserved teeth), and 11.1% (lost teeth) (p=0.037). The percentage of implant loss significantly (p<0.001) increased when the medial/distal bone loss was ≥3 mm. The highest (p≤0.001) pocket depths were found in teeth with ≥5 mm and implants with ≥3 mm bone losses, with similar mean values (≥4 mm), associated with higher rates of plaque index and bleeding by probing.
Conclusions: The significant bi-directional relation between plaque and bone loss, and between each of these two parameters/signs and pocket depths or bleeding (both in teeth and implants, and between them) together with the higher percentage of implants lost when the bone loss of the associated teeth was ≥3 mm suggest that the patient's periodontal status is a critical issue in predicting implant health/lesion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3482539 | PMC |
http://dx.doi.org/10.4317/medoral.17999 | DOI Listing |
J Biomed Mater Res A
January 2025
Department of Periodontics, Dr. R. Ahmed Dental College and Hospital, Kolkata, West Bengal, India.
Chronic osteomyelitis of the maxillofacial bones (i.e., jaw bones) is a persistent infection that requires effective treatment.
View Article and Find Full Text PDFHeliyon
February 2024
Department of Life, Health and Environmental Sciences, Postgraduate School of Orthodontics, Università degli Studi dell'Aquila, Via Piazzale Salvatore Tommasi 1, Abruzzo, L'Aquila 67100, Italy.
Objective: This paper analyses the mechanical response of mini-implants under pull-out, push-in, and shear forces.
Materials And Methods: The authors have devised a specialized testing apparatus, using a universal testing machine, for the mechanical characterisation of orthodontic mini-implants (OMI) installed in pig hard palate. The experimental investigation encompasses seven screw types, each subjected to pull-out, push-in, and shear forces.
Khirurgiia (Mosk)
December 2024
Petrovsky National Research Center of Surgery, Moscow, Russia.
Objective: To demonstrate successful treatment of a patient with aneurysmal lesions of several aortic segments.
Material And Methods: A patient with myelodysplastic syndrome and pancytopenia underwent endovascular repair for abdominal aortic aneurysm. Aneurysm of common iliac artery and borderline thoracic aortic aneurysm occurred 2 years after surgery.
Braz Oral Res
December 2024
Universidade Federal de Uberlândia - UFU, School of Dentistry, Department of Periodontology and Implantology, Uberlândia, MG, Brazil.
The purpose of this study was to evaluate the effect of a single dose of ionizing radiation (30 Gy) on the osseointegration of implants in the rabbit tibia. Twenty rabbits received two dental Morse-tapered junction implants and one implant in each tibia. The animals were randomly divided into two groups (n=10), non-irradiated (NoIr) and irradiated (Ir), wherein the Ir group received a single dose of 30 Gy radiation 2 weeks after implant installation.
View Article and Find Full Text PDFOral Maxillofac Surg
December 2024
Instituto Militar de Engenharia, Praça General Tibúrcio 80, Urca, Rio de Janeiro, 22290-270, Brazil.
Aim: Insertion of dental implants causes bone deformation and induces residual bone compression stress, which can lead to implant failure if the bone loss threshold is exceeded. The current literature about bone stress is restricted to computer simulations and implant primary stability measurements after installation. This work measures the torque and deformation during implant insertion testing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!