Aims: About 30 to 50% of patients undergoing cardiac resynchronization therapy (CRT) may not show clinical or echocardiographic improvement, despite fulfilling guidelines recommendations for CRT. For this reason, we need a more accurate method to assess CRT eligibility. The aims of this study were to verify, on a 12-month follow-up, the usefulness of QT corrected dispersion (QTcD) in a patient's selection for CRT.

Methods: We stratified 53 patients who underwent CRT, into two groups based on the estimation of QTcD, that is, QTcD > 60 ms and QTcD ≤ 60 ms. In all patients were performed New York Heart Association (NYHA) class determination, six-minute walking test, QtcD, and QRS measurements, and complete echocardiographic assessment at 1, 3, 6, and 12 months after implantation.

Results: At baseline, there were no significant differences in clinical, echocardiographic, and electrocardiographic parameters duration between two groups. At 12-month follow-up between the two groups, there were significant differences in NYHA (1.2 ± 0.4 vs 2 ± 0.6; P < 0.01), six-minute walking distance (422 ± 68 vs 364 ± 68; P < 0.01), left ventricular (LV) ejection fraction (34 ± 7% vs 28 ± 6%; P < 0.01), LV end-diastolic diameter (57 ± 7 vs 63 ± 8; P < 0.01), and LV intraventricular dyssynchrony (24 ± 14 vs 39 ± 23; P < 0.01).

Conclusion: This study suggests that QTc dispersion in addition to QRS duration could improve the sensitivity of electrocardiogram in a patient's selection for CRT.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.2012.03402.xDOI Listing

Publication Analysis

Top Keywords

cardiac resynchronization
8
resynchronization therapy
8
corrected dispersion
8
clinical echocardiographic
8
12-month follow-up
8
patient's selection
8
qtcd qtcd
8
six-minute walking
8
crt
5
qtcd
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!