A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Indoor air is a significant source of tri-decabrominated diphenyl ethers to outdoor air via ventilation systems. | LitMetric

Ventilation of indoor air has been hypothesized to be a source of PBDEs to outdoors. To study this, tri-decabrominated diphenyl ethers were analyzed in outgoing air samples collected inside ventilation systems just before exiting 33 buildings and compared to indoor air samples from microenvironments in each building collected simultaneously. Median ∑(10)PBDE (BDE- 28, -47, -99, -153, -183, -197, -206, -207, -208, -209) concentrations in air from apartment, office and day care center buildings were 93, 3700, and 660 pg/m(3) for outgoing air, and 92, 4700, and 1200 pg/m(3) for indoor air, respectively. BDE-209 was the major congener found. No statistically significant differences were seen for individual PBDE concentrations in matched indoor and outgoing air samples, indicating that outgoing air PBDE concentrations are equivalent to indoor air concentrations. PBDE concentrations in indoor and outgoing air were higher than published outdoor air values suggesting ventilation as a conduit of PBDEs, including BDE-209, from indoors to outdoors. BDE-209 and sum of BDE-28, -47, -99, and -153 emissions from indoor air to outdoors were roughly estimated to represent close to 90% of total emissions to outdoor air for Sweden, indicating that contaminated indoor air is an important source of PBDE contamination to outdoor air.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es204122vDOI Listing

Publication Analysis

Top Keywords

indoor air
28
outgoing air
20
air
16
outdoor air
16
air samples
12
pbde concentrations
12
indoor
9
air source
8
tri-decabrominated diphenyl
8
diphenyl ethers
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!