Coronary stent design influences local patterns of wall shear stress (WSS) that are associated with neointimal growth, restenosis, and the endothelialization of stent struts. The number of circumferentially repeating crowns N(C) for a given stent design is often modified depending on the target vessel caliber, but the hemodynamic implications of altering N(C) have not previously been studied. In this investigation, we analyzed the relationship between vessel diameter and the hemodynamically optimal N(C) using a derivative-free optimization algorithm coupled with computational fluid dynamics. The algorithm computed the optimal vessel diameter, defined as minimizing the area of stent-induced low WSS, for various configurations (i.e., N(C)) of a generic slotted-tube design and designs that resemble commercially available stents. Stents were modeled in idealized coronary arteries with a vessel diameter that was allowed to vary between 2 and 5 mm. The results indicate that the optimal vessel diameter increases for stent configurations with greater N(C), and the designs of current commercial stents incorporate a greater N(C) than hemodynamically optimal stent designs. This finding suggests that reducing the N(C) of current stents may improve the hemodynamic environment within stented arteries and reduce the likelihood of excessive neointimal growth and thrombus formation.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2012.2196275DOI Listing

Publication Analysis

Top Keywords

vessel diameter
16
hemodynamically optimal
12
coronary stent
8
stent designs
8
vessel caliber
8
stent design
8
neointimal growth
8
optimal vessel
8
stent
6
vessel
6

Similar Publications

Comprehensive Non-invasive Versus Invasive Approach to Evaluate Cardiac Allograft Vasculopathy in Heart Transplantation: The CCTA-HTx Study.

Circ Cardiovasc Imaging

January 2025

Cardiovascular Center Aalst, Onze-Lieve-Vrouwziekenhuis (OLV) Clinic, Aalst, Belgium (M. Belmonte, P.P., M.M.V., M. Beles, H.O., R.S., G.E., M.S., R.D., W.H., J.V.K., J.B., M.V.).

Background: Coronary computed tomography angiography (CCTA) is emerging as a valuable tool for noninvasive surveillance of cardiac allograft vasculopathy (CAV) in patients with heart transplant (HTx). We assessed the diagnostic performance of a comprehensive CCTA-based approach compared with the invasive reference, which includes invasive coronary angiography, intravascular ultrasound, and fractional flow reserve, for detecting CAV.

Methods: This was a multicenter prospective study including 37 patients with HTx who underwent CCTA, invasive coronary angiography, intravascular ultrasound, and fractional flow reserve.

View Article and Find Full Text PDF

Background: Type 2 diabetes mellitus (T2DM) patients with small-diameter stents (SDS), that are equal to or less than 2.5 mm in diameter, face increased risks of restenosis and complications. This study aimed to evaluate the 1-year follow-up to assess the rate of major adverse cardiac events (MACE) and bleeding risk between ticagrelor and clopidogrel in T2DM patients after SDS implantation.

View Article and Find Full Text PDF

Background: The left internal thoracic artery (LITA) has been widely accepted as the standard for revascularizing the left anterior descending artery during coronary artery bypass grafting (CABG) surgery. However, in 10-20% of cases, the LITA may lead to unsecured side branches to the chest wall, particularly the lateral costal artery (LCA), potentially resulting in postoperative chest angina.

Case Presentation: We report the case of a 58-year-old patient who experienced persistent angina eight months after having undergone coronary artery bypass grafting (CABG) due to the steal phenomenon caused by a thick lateral costal artery (LCA).

View Article and Find Full Text PDF

Background: The outcome of coronary artery bypass grafting (CABG) depends on several factors, including the quality of the distal anastomoses to the coronary arteries. Early graft failure may be caused by, e.g.

View Article and Find Full Text PDF

Characteristics of Peripheral Intravenous Catheter Cannulation in Older Japanese Inpatients.

J Infus Nurs

January 2025

Author Affiliations: Faculty of Nursing, Department of Nursing, Josai International University, Chiba, Japan (Mss Kitada and Tateno; Drs Ninomiya and Kabashim); Faculty of Pharmaceutical Sciences, Department of Medical Pharmacy, Josai International University, Chiba, Japan (Dr Yamamura); Behavioral Science, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, Japan (Dr Hori).

Age-related physiological changes affect various aspects of peripheral intravenous catheter (PIVC) cannulation. However, the characteristics of PIVCs, especially in older patients, have been poorly investigated. In the current cross-sectional observational study, PIVC sizes, PIVC sites, the number of attempts until successful insertion, and the degree of venodilation upon insertion among hospital inpatients aged ≥65 years were investigated, along with measurements of the vessel diameter and depth using ultrasound.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!