To investigate the hypothesis of a sympathetic imbalance in the pathophysiology of digital vasospasms during stress we measured vascular and sympathetic nervous system reactivity during a standardized mental arithmetic test in 12 patients with primary Raynaud's phenomenon in comparison to 12 healthy control subjects. Blood pressure, heart rate, forearm blood flow and fingertip laser Doppler flux were measured together with the venous concentrations of norepinephrine and epinephrine from the back of the hand before and during mental arithmetic in a climate room. No significant differences in circulatory or sympathetic reactivity were found between both groups except for fingertip skin circulation with a small decrease of laser Doppler flux (-11.6%) in controls, whereas it increased in PRP (46.6%; p less than 0.05 between both groups). Baseline skin blood flow was inversely correlated with changes in laser Doppler flux (R = -0.91; p less than 0.001; no. 24) irrespective of the diagnosis when baseline skin bloodflow is low a vasodilatory response occurs and when it is high a vasoconstrictive response is seen. Initial laser Doppler flux was lower while baseline diastolic blood pressure, heart rate and (nor)epinephrine concentrations were significantly higher in Raynaud-patients suggesting an increased sympathetic activity at rest in primary Raynaud's phenomenon.
Download full-text PDF |
Source |
---|
Neural Netw
January 2025
Department of Mechanical Engineering, University of South Carolina, Columbia, SC 29208, USA. Electronic address:
Lamb waves are widely used for defect detection in structural health monitoring, and various methods are developed for Lamb wave data analysis. This paper presents an unsupervised Adversarial Transformer model for anomalous Lamb wave pattern detection by analyzing the spatiotemporal images generated by a hybrid PZT-scanning laser Doppler vibrometer (SLDV). The model includes the global attention and the local attention mechanisms, and both are trained adversarially.
View Article and Find Full Text PDFPhytomedicine
January 2025
Department of Orthopaedics, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, China,; Zhejiang Provincial Key Laboratory of Orthopaedics, Wenzhou 325027, China, ; The Second Clinical Medical College of Wenzhou Medical University, Wenzhou 325027, China. Electronic address:
Background: The significant distal necrosis of the random-pattern skin flaps greatly restricts their clinical applications in flap transplantation. Previous studies have demonstrated the potential of danshensu (DSS) to alleviate ischemic tissue injury. However, no research to date has confirmed whether DSS can improve the survival of ischemic flaps.
View Article and Find Full Text PDFJ Am Heart Assoc
January 2025
Department of Neurosurgery, Center of Pituitary Tumor, Ruijin Hospital Shanghai Jiao Tong University School of Medicine Shanghai China.
Background: Carotid endarterectomy (CEA) is widely used to treat carotid artery stenosis (CAS). However, the effects of CEA on unilateral CAS-induced cognitive impairment and the underlying mechanism remain poorly understood.
Methods And Results: Thirteen patients diagnosed with unilateral severe CAS underwent pre- and post-CEA assessments, including fluoro-2-deoxy-d-glucose positron emission tomography/magnetic resonance imaging, cognitive assessments, and routine blood tests before and after CEA.
We demonstrate a (FMCW) light detection and ranging (LIDAR) system utilizing a (SNSPD) to measure vibrational spectra using reflected signals at the single-photon level. By determining the time-variant Doppler shift of the reflected probe signal, this system successfully reconstructs various audio signals, including pure sinusoidal, multi-tonal, and musical signals, up to 200 Hz, limited by the laser frequency modulation rate and the Nyquist sampling theorem. Additionally, we employ scanning galvo mirrors to perform 3D measurements and map audio signals from different regions in the scanned field of view.
View Article and Find Full Text PDFA parallel Hilbert transform arctangent phase demodulation (PHT-ATAN) method based on overlapping computation is proposed for phase demodulation of laser heterodyne Doppler vibrometers. The method suppresses the end point effects by utilizing overlapping computation and data concatenation and accelerates phase demodulation through parallel processing. Simulation and experimental results demonstrate that when the algorithm's parallelism is ≥4, the computation speed of this method increases by over 100% compared to traditional methods, while maintaining the signal-to-noise ratio and accuracy of the phase demodulation results.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!