Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To develop a clinical decision support system activated at the time of discharge to reduce potentially inappropriate discharges from unidentified or unaddressed abnormal laboratory values.
Methods: We identified 106 laboratory tests for possible inclusion in the discharge alert filter. We selected 7 labs as widely available, commonly obtained, and associated with high risk for potential morbidity or mortality within abnormal ranges. We identified trigger thresholds at levels that would capture significant laboratory abnormalities while avoiding excessive flag generation because of laboratory results that minimally deviate outside the normal reference range.
Results: We selected sodium (>155 or <125 mmol/L), potassium (<2.5 or >6 mEq/dL) phosphorous (<1.6 mg/dL), magnesium (<1.2 mg/dL), creatinine greater than 1.1 with a rise of 20% or more between the 2 most recent results, white blood cell count (>11,000 cells/mm with a rise of 20% or more between the 2 most recent results), and international normalized ratio greater than 4.
Conclusions: A discharge alert filter that reliably and effectively identifies patients that may be discharged in unsafe situations because of unaddressed critical laboratory values can improve patient safety at discharge and potentially reduce the incidence of costly litigation. Further research is needed to validate whether the proposed discharge alert filter is effective at improving patient safety at discharge.